Introduction

ICP Mass Spectrometer offers ultra-trace detection and comprehensive multi-element analysis. These are designed for provide high sensitivity, detecting elements down to parts per trillion, and boast a wide dynamic range. spectrometers are equipped with robust plasma ionization and collision/reaction cell technology, which ensures accurate results. They feature automated sample handling with high efficiency and less manual intervention. These spectrometers are designed with intuitive software for reliable isotope ratio analysis and high-throughput performance.

暂无信息

Standards

European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible

ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers

Complies with the above standards, but is not limited to them.

Features

1. Long-life lamp reduces routine replacement and downtime.

2. Multi-cell or sipper options increase measurement throughput.

3. Diffraction grating or monochromator provides precise wavelength selection.

4. Software tools support spectral scans, standard curves and kinetics.

5. USB, RS232 or printer options export results and reports.

FAQ

What are the main applications of the ICP Mass Spectrometer?

The ICP Mass Spectrometer is used to measure absorbance, transmittance or concentration of samples across a defined wavelength range. It supports quantitative analysis, purity checks, kinetics and quality control in chemistry, biology, pharmaceutical and environmental laboratories.

What standards does the ICP Mass Spectrometer comply with?

The instrument is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for spectrophotometers, including wavelength and photometric accuracy. Procedures should follow applicable standard methods. Compliance documentation can be provided on request.

What warranty comes with the ICP Mass Spectrometer?

The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.

Will staff need special training?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Does the ICP Mass Spectrometer need calibration or verification?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Where do we get replacement parts?

The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.

Can it be adapted to our requirements?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

How is the ICP Mass Spectrometer commissioned?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What should be avoided when using the ICP Mass Spectrometer?

Do not measure highly corrosive or incompatible samples, use dirty cuvettes or skip blank correction. Verify wavelength and photometric accuracy periodically. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.