Introduction

Single Station Glove Box features a sealed stainless steel chamber, maintaining moisture and oxygen levels below 1 ppm. It includes a gas purification system supporting nitrogen and argon circulation at 90 m³/h. The -controlled system maintains automatic pressure regulation within ±15 mbar for stable operation. Equipped with butyl rubber gloves, 0.4 mm thick, for secure and precise material handling. Ideal for handling sensitive materials in research and industrial applications.

This glove box is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Single Station Glove Box maintains ultra-low moisture and oxygen levels, ideal for semiconductor fabrication, battery research, and chemical synthesis. Its automated purification and pressure control system ensure efficiency in inert gas applications.

Specifications

Working Gas Nitrogen, Argon, Helium
Water & Oxygen Index Less than 1 ppm
Circulation Capacity Integrated fan, 90m³/h
Material 304 stainless steel, 3mm thick
Internal Dimensions 1220 × 750× 900mm
Window Tempered glass, 8mm thick
Glove Ports Anodized aluminum, O-ring enclosed
Gloves Butyl rubber, 0.4mm thick, Ø 7 inch
Pressure Control controlled, ±15 mbar
Big Passing Box Ø 360mm × 600mm, double-gate, anodized aluminum, 10mm thick
Small Passing Box Ø 100mm × 300mm, double-gate, screw-threaded coupling
Filter 0.3μm (0.12μm optional)
Shelf Stainless steel, 2 levels
Lighting Fluorescent lamp
Gas Purification Dehydration & deoxidization with 4.5kg copper catalyst, 4.5kg molecular sieve
Purification Capacity Deoxidization: 36L, Dehydration: 1.3kg
Gas Cycling System Nitrogen/Argon, 90m³/h, frequency conversion
Regeneration Gas 5-10% hydrogen mixed gas
Vacuum Pump 12m³/h rotary pump (8m³/h optional)
Main Valve DN 40 KF, electronic pneumatic
Control Valve Electronic pneumatic valve
Control System Siemens , touch panel
Foot Switch Controls box pressure
Display System Siemens , pressure display
Power Supply 220V
Dimension (L×D×H) 1220 × 750 × 900mm
Overall Dimension 1225 × 1810 × 982mm
Net Weight 560kg
Gross Weight 760kg

Features

Real-time monitoring with touchscreen display

Integrated vacuum pump system

Supports nitrogen and argon operation

Integrated lighting system

Efficient gas purification unit

Adjustable working pressure settings

Easy maintenance and system calibration

Anti-reflective front panel

Overload protection safety system

FAQs

1. What types of materials can be handled inside the Single Station Glove Box?

Single Station Glove Box is ideal for handling sensitive materials that require a controlled, inert atmosphere. It can be used for various applications, including research and industrial processes involving materials that are sensitive to oxygen and moisture. The glove box’s low oxygen and moisture levels ensure safe handling of materials like powders, chemicals, and electronic components. This makes it perfect for both delicate and high-stakes operations.

2. How easy is it to maintain and clean the Single Station Glove Box?

The Single Station Glove Box is designed for easy maintenance with an automated cleaning system that ensures efficient gas replacement and purification. The vacuum pump and gas purification system can be easily checked and serviced. Additionally, its sealed design minimizes contamination risks, making regular cleaning tasks straightforward and time-saving.

3. What safety measures are integrated into the Single Station Glove Box?

The Single Station Glove Box is equipped with automatic pressure regulation, overload protection, and a sealed chamber to prevent leaks. The control system ensures that pressure fluctuations are managed safely, reducing the risk of accidents while working with sensitive materials.

4. How frequently does the gas purification system of the Single Station Glove Box need maintenance?

Single Station Glove Box gas purification system has a long lifespan, but it’s important to check it periodically for optimal performance. glove box is designed for easy filter changes, and regenerating the purification system ensures its continued efficiency. The frequency of maintenance depends on usage conditions and how often the system is in operation.

5. How does Single Station Glove Box maintain a contaminant-free environment?

Single Station Glove Box ensures a contaminant-free workspace with an advanced gas purification system that removes moisture and oxygen. The continuous circulation of purified gases like nitrogen or argon maintains a stable internal atmosphere. The sealed stainless steel chamber prevents external contamination, while airtight glove ports provide secure handling. Automated pressure regulation further enhances safety by preventing fluctuations that could affect sensitive materials.

6. How does the pressure regulation system of the Single Station Glove Box work?

The Single Station Glove Box features a -controlled pressure regulation system that maintains internal pressure within ±15 mbar. Automatic adjustments prevent sudden fluctuations, ensuring stability for delicate processes. The foot switch allows easy control, while electronic pneumatic valves provide precise pressure management. These features enhance safety and prevent damage to sensitive samples.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.