Introduction

Heating Circulator is designed for offer temperatures of RT+5 to 160°C (degrees Celsius) or 250°C (degrees Celsius). They offer fully enclosed circulation systems to reduce fluid evaporation, contamination, and oxidative damage. These come with LCD displays and PID controls for reliable temperature regulation and an intuitive interface. Their real-time liquid level monitoring ensures smooth operation. Circulator delivers consistent thermal performance for various lab and industrial processes.

Heating Circulator T-HTC-L2102

Heating Circulator T-HTC-L2102

Heating Circulator offers reservoir capacity of 15 liters. It features PID-based temperature control that ensures stable heating performance. Equipped with caster wheels, it provides easy ...
Heating Circulator T-HTC-L2103

Heating Circulator T-HTC-L2103

Heating Circulator has flow rate of 42 L/min. It features an external PT100 sensor port for connecting advanced probes to monitor exterior system temperatures. Equipped with overcurrent pr...
Heating Circulator T-HTC-L2100

Heating Circulator T-HTC-L2100

Heating Circulator offers working temperatures from RT to 200℃. It features built-in circulation filter to keep internal pipeline free from debris and blockages. Equipped with bath liquid...
Heating Circulator T-HTC-L2101

Heating Circulator T-HTC-L2101

Heating Circulator has maximum temperature of 200℃. It features real time liquid level display for constant visibility and tracking of fluid inside the reservoir. Equipped with leakage pr...
Heating Circulator T-HTC-S2102

Heating Circulator T-HTC-S2102

Heating Circulator offers temperatures up to 250℃ and 13-liter volume. It features dedicated inlet and outlet for external cooling water integration into system. Equipped with overload an...
Heating Circulator T-HTC-S2103

Heating Circulator T-HTC-S2103

Heating Circulator comes with working temperature of RT+5 to 250℃. It features PID control technology for stable, responsive temperature regulation and minimal fluctuation. Equipped with ...
Heating Circulator T-HTC-S2100

Heating Circulator T-HTC-S2100

Heating Circulator offers temperature range of RT +5 to 250℃. It features sealed circulation loop to prevent oxidation, degradation, and evaporation of thermal fluids. Equipped with real-...
Heating Circulator T-HTC-S2101

Heating Circulator T-HTC-S2101

Heating Circulator offers maximum temperature of 160℃. It features digital LCD interface for clear viewing and adjustment of operating parameters and status. Equipped with an internal coo...

Standards

DIN 12876-1-Laboratory electrical equipment-Laboratory circulators and thermostats

Complies with the above standards, but is not limited to them.

Features

1. Precise temperature control with a clear digital display.

2. Adjustable high-limit cut-off adds independent protection.

3. Open bath or closed loop options suit different applications.

4. Adjustable over-temperature cut-off protects samples and the unit.

5. Timer and continuous modes support varied protocols.

FAQ

What are the main applications of the Heating Circulator?

The Heating Circulator is used to heat or circulate water or heat-transfer fluid for precise temperature control of samples, reactors and instruments. It supports chemistry, biology, calibration and quality-control work needing stable bath temperatures.

Which standards and regulations apply to the Heating Circulator?

The unit is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for laboratory temperature-control baths. Calibration and test procedures should follow applicable methods. Compliance documentation can be provided on request.

What does the warranty cover?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

Is the Heating Circulator difficult to operate?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Where do we get replacement parts?

The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.

Can it be adapted to our requirements?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

How is the Heating Circulator commissioned?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What should be avoided when using the Heating Circulator?

Do not run dry, use fluids outside their rated range or exceed the bath temperature limit. Keep the bath clean and avoid flammable media above their flash point. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry