Introduction

Hyperspectral Camera offers a spectral range of 400 to 1000 nm with a raw resolution of 640 × 512 pixels, ensuring detailed and accurate imaging. It features a high-resolution HgCdTe deep-cooled sensor for enhanced sensitivity and clarity. The camera features push-broom imaging, capturing data line-by-line for detailed analysis. Its advanced Stirling refrigeration cooling system maintains stable performance across a wide operating temperature range. Our compact and lightweight camera is ideal for applications requiring precise and reliable hyperspectral imaging. This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Hyperspectral Camera is widely used for monitoring plant health, detecting pests, analysing disasters, assessing water quality, mapping minerals, evaluating soil pollution, and classifying urban geological substances.

Specifications

Spectral Range 400 to 1000 nm
Detector Type - Hyperspectral Camera
Spectral Channels 512
Spatial Channels 640
Field of View () 15.2° at f = 35 mm (Lens changeable)
Instantaneous () 0.7 mrad at f = 35 mm (Lens changeable)
Raw Resolution 640 × 512 pixels
Raw Pixel Size 15 µm × 15 µm
Bit Depth 16 bits
Noise Equivalent Temperature Difference () <17 mK
Frame Rate (Max) 120 fps
Detector Interface Camlink
Operating Temperature -20 to 50℃
Storage Temperature -30 to 70℃
Data Format Compatible with
Power Consumption <10W
Power Supply 5V and 12V ±10%
Target Surface Dimensions 9.6 × 7.68 mm
Dimensions 226 mm × 98 mm × 85 mm
Weight 1.18 kg

Features

Adjustable Field of View

Extensive spectral and spatial channels

High dynamic range

Ultra-sensitive

High frame rate

Flexible interface

Low power consumption

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.