Introduction
Xenon Aging Test Chamber has a 32 GJB150.7A, GBT2423.24-2013, and other testing requirements. This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Xenon Aging Test Chamber simulates various environments for testing and research, assessing material changes under sunlight exposure and aiding in material development and quality control.Specifications
| Capacity | 32 L |
| Temperature Range | 0℃ to 80℃ |
| Blackboard Temperature | +45℃ to +90℃ (±3℃) |
| Temperature Deviation | ±2℃ (without lighting) |
| Temperature Resolution | 0.1℃ |
| Temperature Fluctuation | ±0.5℃ (without lighting) |
| Effective Irradiation Area | 625 cm² |
| Door Opening Method | Single door, opens from right to left |
| Sample Holder | Flat, height-adjustable, suitable for special-shaped samples |
| Sample Space | Three-quarters of the total space; no heat load |
| Humidity Range | 20% to 95% R.H |
| Humidity Deviation | ±3% R.H (without lighting) |
| Humidity Fluctuation | ±2.5% R.H (without lighting) |
| Light Source | Full-spectrum air-cooled Xenon lamp |
| Lamp Power | 1.8 KW |
| Sensor | Irradiance sensor |
| Irradiance Monitoring Method Narrow Band | 340 nm / 420 nm |
| Irradiance Monitoring Method Broad Band | 280 to 800 nm / 300 to 400 nm |
| Adjustable Light Irradiance Range | 0.35 to 0.70 W/m² (at 340 nm) 0.35 to 1.25 W/m² (at 420 nm) 180 to 1200 W/m² (at 280 to 800 nm) 30 to 60 W/m² (at 300 to 400 nm) |
| Spray Function | Indirect continuous spray; manual pure water supply |
| Function Modes | Alternating: Irradiation mode, Dark mode, Spray mode |
| Ambient temperature | 25℃ ±3℃ |
| Condenser | 5 to 25℃ ±3℃ |
| Refrigerant | R404a |
| Relative humidity | ≤85% |
| Air pressure | 86 kPa to 106 kPa |
| Inner Material | #304 mirror stainless steel |
| External Material | Cold-rolled steel plate with spray paint |
| Duct Circulation | Centrifugal circulation motor |
| Door Lock | Flat handle lock; door opens from left to right |
| Controller | 7-inch touch screen controller Power switch Running indicator data download interface |
| Power Cable | Equipped with drain outlets and a 2.5 m national standard cable at the back |
| Water Supply | Pure water or distilled water manually added into the water tank Customization for auto water supply available |
| Frequency | 50 Hz (Customization for 60 Hz available) |
| Protection Grounding Resistance | ≤4Ω |
| Maximum Current | 10A |
| Power Consumption | 4.0 KW |
| Power Supply | AC 380 V ±10% with protection grounding (Customization for 220 V available) |
| Interior Dimension | 350 × 300 × 300 mm |
| Exterior Dimension | 900 × 900 × 770 mm |
| Packaging Dimension | 900 ×900 × 102 mm |
| Gross Weight | 196 Kg |
| Net Weight | 142 Kg |
Features
7-inch touch screen controller
Convenient operation
Large storage space
interface
FAQs
1. What are the key factors to consider when selecting this test equipment for laboratory use?
When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this test equipment be calibrated to ensure accurate results?
It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this test equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the test equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.