Introduction

Xenon Aging Test Chamber has a 32 GJB150.7A, GBT2423.24-2013, and other testing requirements. This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Xenon Aging Test Chamber simulates various environments for testing and research, assessing material changes under sunlight exposure and aiding in material development and quality control.

Specifications

Capacity 32 L
Temperature Range 0℃ to 80℃
Blackboard Temperature +45℃ to +90℃ (±3℃)
Temperature Deviation ±2℃ (without lighting)
Temperature Resolution 0.1℃
Temperature Fluctuation ±0.5℃ (without lighting)
Effective Irradiation Area 625 cm²
Door Opening Method Single door, opens from right to left
Sample Holder Flat, height-adjustable, suitable for special-shaped samples
Sample Space Three-quarters of the total space; no heat load
Humidity Range 20% to 95% R.H
Humidity Deviation ±3% R.H (without lighting)
Humidity Fluctuation ±2.5% R.H (without lighting)
Light Source Full-spectrum air-cooled Xenon lamp
Lamp Power 1.8 KW
Sensor Irradiance sensor
Irradiance Monitoring Method Narrow Band 340 nm / 420 nm
Irradiance Monitoring Method Broad Band 280 to 800 nm / 300 to 400 nm
Adjustable Light Irradiance Range 0.35 to 0.70 W/m² (at 340 nm)
0.35 to 1.25 W/m² (at 420 nm)
180 to 1200 W/m² (at 280 to 800 nm)
30 to 60 W/m² (at 300 to 400 nm)
Spray Function Indirect continuous spray; manual pure water supply
Function Modes Alternating: Irradiation mode, Dark mode, Spray mode
Ambient temperature 25℃ ±3℃
Condenser 5 to 25℃ ±3℃
Refrigerant R404a
Relative humidity ≤85%
Air pressure 86 kPa to 106 kPa
Inner Material #304 mirror stainless steel
External Material Cold-rolled steel plate with spray paint
Duct Circulation Centrifugal circulation motor
Door Lock Flat handle lock; door opens from left to right
Controller 7-inch touch screen controller
Power switch
Running indicator
data download interface
Power Cable Equipped with drain outlets and a 2.5 m national standard cable at the back
Water Supply Pure water or distilled water manually added into the water tank
Customization for auto water supply available
Frequency 50 Hz (Customization for 60 Hz available)
Protection Grounding Resistance ≤4Ω
Maximum Current 10A
Power Consumption 4.0 KW
Power Supply AC 380 V ±10% with protection grounding (Customization for 220 V available)
Interior Dimension 350 × 300 × 300 mm
Exterior Dimension 900 × 900 × 770 mm
Packaging Dimension 900 ×900 × 102 mm
Gross Weight 196 Kg
Net Weight 142 Kg

Features

7-inch touch screen controller

Convenient operation

Large storage space

interface

FAQs

1. What are the key factors to consider when selecting this test equipment for laboratory use?

When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this test equipment be calibrated to ensure accurate results?

It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this test equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the test equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.