Introduction
Optical Emission Spectrometer operates over a wavelength range of 165 to 1000 nm. The circuit type is a solid-state RF power supply designed with an automatic matching function to optimize power delivery and stability during operation. It uses a middle-step grating, enhancing spectral resolution and light dispersion. Our Optical Emission Spectrometer includes a three-way gas control for precise adjustment of plasma, auxiliary, and carrier gas flows, enhancing overall performance and stability.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Optical Emission Spectrometer is used to analyze trace elements in substances soluble in nitric, hydrochloric, and hydrofluoric acids, in fields like environmental protection, petroleum, rare earths, semiconductors, geology, metallurgy, clinical medicine, food safety, forensics, and agriculture.
Specifications
| Wavelength Range | 160 to 1000 nm |
| Grating | Middle step grating, 52.67 lp/mm, 64° sparkle angle |
| Numerical Aperture | F < 8, ultra-high luminous flux |
| Target Size | 27.6 mm x 27.6 mm, 1024 x 1024 addressing detection units |
| Resolution | < 0.0065 nm at 200 nm |
| Astigmatism | Equivalent background concentration of 10000 ppm Ca solution at As 189.042 nm < 2 ppm |
| Light Chamber | Precision constant temperature, 35 ± 0.1°C, nitrogen purging (normal: 1.8 L/min, fast: 3.8 L/min) |
| Plasma Argon Flowmeter | 100 to 1000 L/h (1.6 to 16 L/min) |
| Auxiliary Argon Flowmeter | 100 to 1000 L/h (0.16 to 1.6 L/min) |
| Auxiliary Carrier Argon Flowmeter | 100 to 1000 L/h (0.16 to 1.6 L/min) |
| Pressure Maintaining Value | 0 to 0.4 MPa |
| Cooling Water Temperature | 20 to 25°C |
| Cooling Water Flow Rate | > 5 L/min |
| Cooling Water Hydraulic Pressure | > 0.1 MPa |
| Output Working Coil Inner Diameter | 25 mm |
| Torque Tube | Three concentric, external diameter 20 mm |
| Coaxial Nebulizer | Outer diameter 6 mm |
| Double Barrel Atomizing Chamber | Outer diameter 34 mm |
| Circuit Type | Solid-state RF Power supply, with auto match function |
| Frequency | 27.12 MHz ± 0.05% |
| Frequency Stability | < 0.1% |
| Power Output Stability | < 0.3% |
| Escaped RF Radiation | 30 cm away from instrument, Electric Field: E < 2 V/m |
| Power Consumption | 800 to 1500 W |
| Power Supply | 220V, 30A |
| Dimension | 1050 × 793 × 745mm |
| Packaging Dimension | 1250 × 950 × 900 mm |
| Weight | 105 Kg |
| Gross Weight | 120Kg |
Features
Fully automatic matching technology
Stable performance
Sample injection automation
, FF, and modes for flexible data logging
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.