Introduction
Automated Microwave Digestion System employs microwave energy for fast and uniform heating. They are integrated with sensors which continuously monitor and control temperature and pressure. Their multi-sample capacity, allows simultaneous digestion of multiple samples. They are constructed from imported TFM, which is highly resistant to chemical and heat. Automated Microwave Digestion System is equipped with a high-power corrosion-proof air blower for air exhaust.
Automated Microwave Digestion System T-MDS-S2110
Automated Microwave Digestion System T-MDS-S2108
Automated Microwave Digestion System T-MDS-S2109
Automated Microwave Digestion System T-MDS-S2105
Automated Microwave Digestion System T-MDS-S2106
Automated Microwave Digestion System T-MDS-S2107
Automated Microwave Digestion System T-MDS-S2104
Automated Microwave Digestion System T-MDS-S2103
Automated Microwave Digestion System T-MDS-S2101
Automated Microwave Digestion System T-MDS-S2102
Automated Microwave Digestion System T-MDS-S2100
Standards
EPA Method 3051A-Microwave assisted acid digestion of sediments, sludges, soils, and oils
Complies with the above standards, but is not limited to them.
Features
1. Rotors hold multiple vessels for parallel sample preparation.
2. Data export supports analytical records.
3. Clear software displays temperature, pressure and step.
4. Temperature and pressure monitoring protect vessels.
5. Program libraries store methods for different matrices.
FAQ
What are the main applications of the Automated Microwave Digestion System?
The Automated Microwave Digestion System is used for microwave heating, digestion, synthesis or sample preparation in the laboratory. It supports analytical, chemical, environmental and materials work requiring controlled, rapid heating.
What standards does the Automated Microwave Digestion System comply with?
The unit is designed with reference to IEC 61010 electrical safety, applicable microwave digestion or synthesis practice and relevant GB/T standards. Vessels and programs must follow the method. Compliance documentation can be provided on request.
How long is the warranty period?
A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.
How easy is the Automated Microwave Digestion System to use?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Is calibration included?
Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.
Where do we get replacement parts?
Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.
Can the Automated Microwave Digestion System be customised?
Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.
Do you provide on-site installation?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What maintenance and safety points matter?
Do not use unsealed or incompatible vessels, exceed pressure or temperature limits or run empty. Follow digestion chemistry and pressure-safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.