Introduction

Ultrapure Water System is a multi-filter unit that produces 10 liters of purified water per hour. It is made of engineering plastic with powder coating technology, which improves water quality and quantity. Our water system requires an inlet water pressure between 0.15 and 0.5 megapascals for optimal operation. Features a built-in 10μm stainless steel filter mesh and silicone soft scraping for continuous cleaning. It integrates water quality sensors and switch signals for accurate monitoring and control.

This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Ultrapure Water System is ideal for cleaning glassware, physical and chemical testing, biochemical analysis, blood examination, microanalysis, , IC, GC, and other analytical experiments

Specifications

Water Output Rate 10L/Hr
Water Flow Rate 1.5 to 2L/min (with pressure barrel)
Water Temperature 5 to 40°C
Inlet Water Pressure 0.15 to 0.5mpa
Concentration < 400 ppm
Water Requirements Urban Tap Water, RO Water, UP Water ( type I grade water)
RO Water Ion Rejection Rate 97 to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate > 99% when MW >200 Dalton
RO Water Particle and Bacterial Rejection > 99%
UP Water Resistivity 18.25 MΩ.CM at 25°C
UP Water Total Organic Carbon (Toc) <10 ppb
UP Water Heavy Metal Ion <0.01 ppb
Bacteria <0.01 cfu/ml (With Terminal Filter)
Particulate Matter (>0.1 Microns) <1/ml
Pyrogen (endotoxin) < 0.001 Eu/ml
Display Color touchscreen
Materials Engineering Plastic Case, Powder Coating Technology
Interface
Power Consumption 120W
Power Supply 110 to 240V, 50/60Hz
Dimensions 550 × 630 × 680 mm
Weight 42 Kg

Features

Equipped with color touchscreen display

High adsorption efficiency and long lifespan

Inbuilt feed water pressure test gauge

Includes pen for measuring dissolved solids

Automatic reminder for filter replacement

FAQs

1. What are the key factors to consider when selecting this water purification system for laboratory use?

When selecting this water purification system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this water purification system be calibrated to ensure accurate results?

It is recommended to calibrate this water purification system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this water purification system?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this water purification system be used with different types of samples, and are there any compatibility considerations?

Yes, this water purification system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the water purification system malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.