Introduction
Fetal Monitor can measure Fetal heart rate in a range of 50 to 240 bpm. Includes a special high-sensitive transducer with a frequency of 1.0MHz. A 12.1-inch color screen is fitted that displays parameters for , , and Fetal movement. It can store up to 42 hours of data, with playback and print capabilities. Utilizes technology for real-time identification and measurement of , providing accurate and reliable results. This medical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Fetal Monitor provides continuous monitoring of fetal heart rate () and uterine contractions. It is utilized in medical facilities, clinical settings, and prenatal care centers.Specifications
| Parameters | Fetal Heart Rate 1 (), FHR2 |
| Measurement Range | 50 to 240 bpm |
| Accuracy | ±2 bpm |
| Sweep Speed | X1, X2, X4, X8 |
| Transducer | 9 crystals, pulsed Doppler, |
| Transducer Frequency | 1.0MHz |
| Transducer Probe | wired |
| Uterine Activity Measurement Range | 0 to 100 |
| Uterine Activity Baseline | 0, 5, 10, 15, 20 (selectable) |
| Maternal /HR () Lead Type | 5-lead |
| Lead Selection | RA, LA, RL, LL, V |
| HR Measurement Range | 15 bpm to 300 bpm |
| HR Accuracy | ±1 bpm or ±1 %, |
| Respiration Rate Range | 7 rpm to 120 rpm |
| Respiration Accuracy | ±2 rpm/min or ±2 % |
| Non-Invasive Blood Pressure () Method | Automatic Oscillometric |
| Parameters | // |
| Operating Modes | Manual/Auto |
| Auto Measure Intervals | 3/5/10/20/30/60/90/120/240 minutes |
| Units | mmHg/kPa |
| Cuff Pressure Range | 0 mmHg to 300 mmHg (0 kPa - 40.0 kPa) |
| Measurement And Alarm Range | : 50 mmHg - 240 mmHg (6.7 kPa - 32.0 kPa) : 25 mmHg - 200 mmHg (3.4 kPa - 26.6 kPa) : 15 mmHg - 180 mmHg (2.0 kPa - 24.0 kPa) |
| Accuracy | ±3 mmHg (±0.4 kPa) or ±2 of reading |
| Over-Pressure Protection | Yes |
| Maternal SpO2 Measurement Range | 70 to 99 % |
| Maternal SpO2 Accuracy | ±3 % |
| PR Range | 30 to 240 bpm |
| PR Accuracy | ±2 bpm/min or ±5 % reading |
| Temperature Range | 0 to 50℃ |
| Temperature Resolution | ±0.1℃ |
| Battery | 2200mAh/14.8V Li-Ion battery |
| Battery Life | 4 hours |
| Power Supply | 100 to 240V |
| Dimensions (L × W × H) | 350 × 320 × 85 mm |
| Weight | 3.5kg |
Features
The screen can be foldable up to 90 degrees
Lightweight and space-saving
Can be connected to an obstetrical central station
Integrated alarm system
Operates with low ultrasound power
Features automatic FM testing
FAQs
1. What are the key factors to consider when selecting this medical equipment for laboratory use?
When selecting this medical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this medical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this medical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this medical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this medical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this medical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the medical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.