Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It is provided with deuterium hollow cathode lamp to eliminate the interference of molecular absorption and Titanium Burner to improve the analysis efficiency and accuracy of the flame. The autosampler has integrated graphite furnace design with high-precision syringes to enter volume as minimum as 0.5μl with intelligent online dilution and concentration function. It has great applications research and medicine, environmental science and other industries.

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Atomic Absorption spectrophotometer is used in scientific research, quality control, disease control, environmental protection, metallurgy, agriculture, chemical industry, and analysis of samples, equipment maintenance, simple and convenient.

Specifications

Wavelength range 180 – 900 nm
Spectral Bandwidth 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs/30 min (Static)≤ ± 0.005 Abs/30 min (Dynamic)
Sample Volume 1 - 100 μl
The volume of sample better than 1 %(at the time of 10 mL - 100 mL)
Repeated Sampling Frequency up to 99 Times
Cleaning and waste container volume Each 500 mL
Absorbance Range 0 - 4 A
The Program Automatic temperature control up to 20 order
Temperature Range room temperature to 3000 ℃
Detector imported photomultiplier tube
Heating Mode vertical heating
Temperature Control Method Vertical optical temperature monitoring graphite tube wall temperature
Temperature Control The furnace enriched up to 20 times
Lamp holder ≤ 6 lamps automatic turret, automatic alignment
Lamp power supply mode pulsed power supply
Optical System Large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristics Volume 0.5 × 10-12g (Cd)
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit 0.4 × 10-12g (Cd)
Detection Limit (Cu) 0.002 μg/mL
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision ≤ 0.5
Ignition Type Microcomputer control, automatic ignition
Sample Tray 70 sample cups, 6 reagent cup
The Smallest Lincrement 0.1 μl
Safety measures The graphite tube damage, water flowAir pressure and other alarm temperature overheating protection
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The Cooling Water Can choose cooling water circulation system
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA

Features

High precision automatic optical system

Graphite furnace temperature control

High technical indicators

Deuterium lamp for background correction system

Polymer automization chamber

Powerful, intelligent user-friendly design

Automatic analysis & Sampler

FAQs

1. What role does the atomic absorption spectrophotometer's deuterium lamp serve in background correction?

’s deuterium light is specifically included in the system for background correction, which ensures reliable analytical findings by removing molecular absorption interference.

2. How much electricity does the atomic absorption spectrophotometer consume to run?

operates at a frequency of 60/50 Hz and needs a power source of 110/220 V with a tolerance of +5% to -10%. The product requires 5000 VA of electricity.

3. How does the atomic absorption spectrophotometer differ in terms of parameters, particularly spectral bandwidth?

atomic absorption spectrophotometer offers greater versatility and precision in spectral analysis with its automated spectrum bandwidth of 0.1, 0.2, 0.4,1.0, and 2.0 nm.

4. What is an Atomic Absorption Spectrophotometer?

An analytical tool called an Atomic Absorption Spectrophotometer () uses the light that each element's atom absorbs to determine the concentration of that element in a sample.

5. What lies behind atomic absorption spectrophotometry's concept?

The basis of spectrophotometry is the light uptake by unbound atoms in a gaseous state. An excited state is created when atoms in the ground state absorb light energy at particular wavelengths. Analyte content in the sample can be calculated by determining the amount of light consumed.

6. What are the different components of an Atomic Absorption Spectrophotometer?

The components include an atomizer (commonly used atomizers are Flame atomizers and Electro thermal atomizers), a Radiation source, and a spectrophotometer.

7. What role does the hollow cathode lamp play in an atomic absorption spectrophotometer's operation?

The hollow cathode lamp in atomic absorption spectrophotometer emits distinctive light at particular wavelengths that match the target analyte. This guarantees that the analyte atoms are excited selectively, resulting in exact and reliable readings.

8. What are the main characteristics of your Atomic Absorption Spectrophotometers?

Atomic Absorption Spectrophotometers boast flexible atomization technologies, accurate optical systems, a titanium combustion head, and a polymer explosion-proof spray chamber. These elements guarantee accurate and effective trace element analysis, along with improved safety and longevity.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.