Introduction

Benchtop Ion meter for Cd, comes with (Cd) cadmium ion selective electrode for cadmium ion concentration measurement. This Ion meter comes with ± 1 % F.S. measurement accuracy. Its direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.

This water testing equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Benchtop Ion meter is used to measure the cadmium ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.

Specifications

Ion measurement range Cd range: 1×106– 1M, 0.01-11200 ppm
Ion measurement accuracy ± 1 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
mV range (-1999.9) to 1999.9 mV
mV accuracy ± 0.2 mV
mV resolution 0.1 mV
Temperature measurement range 0 to 105 °C, 32 to 221 °F
Temperature accuracy ± 0.5 °C, ± 0.9 °F
Temperature resolution 0.1°C
Temperature compensation 0 to 100 °C, 32 to 212 °F
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Power off Manual or automatic (10,20,30 minutes)
Memory Stores up to 500 sets of data
Output communication interface
Connector
Display (130 × 110 mm)
Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
Dimension (L × W × H) 210 × 188 × 60 mm
Weight 1.5 kg

Features

Large display

2 - 5 points calibration from low to high concentration

Direct ion concentration readout for elaborate measurement process

Selectable concentration units from ppm, mg / L, mol / L

mV measurements to check the performance of ion selective electrode

Temperature compensation provides accurate reading over the entire range

Stability indicator to show current measurement status

Calibration due reminder for regular calibration of the meter

Auto hold function to freeze stable reading for better viewing & recording

Automatic electrode diagnosis shows the slope of the sensor

Reset setting function

Expanded memory stores and recalls up to 500 readings

Built –in real time clock stamps

communication interface to transfer stored data to PC

FAQs

1. What types of water samples can be tested using the It Benchtop Ion meter for Cd, for cadmium ion concentration?

It Benchtop Ion meter for Cd is designed to detect cadmium ions in a variety of water sources, including potable water, distilled/deionized water, industrial wastewater, and natural surface water. This makes it suitable for environmental monitoring, water treatment facilities, and research laboratories. It has a wide measurement range of 0.01 to 11200 ppm which allows for detection in both trace and high-level contamination. This versatility ensures accurate cadmium monitoring across different water types and industries.

2. How does the Benchtop Ion meter for Cd support users in performing multi-point calibrations?

The Benchtop Ion meter for Cd supports 2 to 5 calibration points, enabling users to create accurate calibration curves over a range of cadmium concentrations. This flexibility allows for greater precision, especially when testing samples with varying ion levels. The system menu allows users to adjust calibration parameters with ease. This ensures that the device remains accurate over time and under different measurement conditions.

3. What features help users ensure the cadmium ion selective electrode of Benchtop Ion meter for Cd remains in good working condition?

Benchtop Ion meter for Cd includes a mV measurement function that can be used to evaluate the electrode's performance and slope, helping users detect electrode degradation. Regular checks in mV mode can indicate when cleaning or replacement is necessary. This proactive maintenance extends electrode life and ensures consistent results. It also reduces the risk of inaccurate measurements caused by a faulty sensor.

4. Is the Benchtop Ion meter for Cd suitable for long-term projects that require data recording and traceability?

Yes, Benchtop Ion meter for Cd is ideal for long-term or repetitive testing as it can store up to 500 sets of data. Each record is time-stamped using the built-in real-time clock, making it easy to track trends or perform audits. This is especially helpful in regulated environments such as water testing labs or environmental studies. Data can also be exported to a PC via for further analysis or reporting.

5. How does the Benchtop Ion meter for Cd ensure accuracy across various temperature conditions during cadmium testing?

The Benchtop Ion meter for Cd offers automatic or manual temperature compensation over a wide range of 0–100°C. This allows the meter to correct readings for temperature fluctuations, ensuring accurate and reliable results in both field and lab settings. It is useful in applications where environmental conditions are not tightly controlled. The built-in temperature probe provides real-time data to support this function.

6. What precautions or reminders does the Benchtop Ion meter for Cd offer to support safe and proper operation over time?

Benchtop Ion meter for Cd includes a calibration due reminder, prompting users to recalibrate at preset intervals to support safe and effective use. This ensures that the device remains accurate and compliant with lab protocols. In addition, the reset function allows users to restore system settings if needed, maintaining operational stability. These features help minimize risks associated with outdated calibrations or misconfigured settings.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.