Introduction
A UV air sterilizer is a device that uses ultraviolet (UV) light, typically at a wavelength of 254 nm, to inactivate microorganisms in the air, providing disinfection of the air in enclosed spaces, and it is used in healthcare facilities, laboratories, food processing, offices, and other indoor environments for infection control and air quality improvement. The sterilizer consists of UV lamps that emit germicidal UV-C light, a housing or duct in which the air is exposed to the light, a fan or the air handling system that moves the air past the lamps, and, in some models, filters; the UV-C light damages the DNA and RNA of microorganisms, such as bacteria, viruses, and mold spores, preventing them from reproducing and causing infection, and the air is disinfected as it passes through the device, and UV air sterilizers are available in various configurations, including portable units that are placed in a room, wall-mounted units, and in-duct units that are installed in the HVAC system, and the UV lamps are shielded or positioned so that people are not exposed to the UV radiation. UV air sterilizers are used in hospitals and clinics for reducing airborne pathogens, in laboratories for reducing contamination, in food processing and pharmaceutical facilities, in offices and public buildings, in schools, in animal facilities, and in many other environments, and they are used continuously or intermittently, with features such as lamp replacement indicators and air flow control. With their effective disinfection of air, UV air sterilizers are important for infection control and indoor air quality.
UV Air Sterilizer LUAS-T2012
UV Air Sterilizer is a space-saving sterilizer utilizes air purifying technology for air sterilization and purification to effectively clean the air. Our sterilizer offers 2000 m³/h of ...
UV Air Sterilizer LUAS-T2011
UV Air Sterilizer is a portable UV air sterilizer with air purifying technology offers working temperature range from 0 to 39℃ with air circulation of ≥800 m3/h. Features air dynamic d...
UV Air Sterilizer LUAS-T2010
UV Air Sterilizer is a portable UV air sterilizer with air purifying technology offers working temperature range from 0 to 39℃ with air circulation of ≥600 m3/h. Features air dynamic d...
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
Complies with the above standards, but is not limited to them.
Features
1. UV air sterilizer for air disinfection using ultraviolet germicidal irradiation.
2. UV-C light for inactivating bacteria, viruses and microorganisms in air.
3. Suitable for hospitals, laboratories, food processing, offices and public spaces.
4. Includes UV lamps, chamber, fan, filter, timer and operation manual.
5. Supports air disinfection for infection control, contamination prevention and safety.
FAQ
Q1: What testing scenarios is this sterilizer mainly applied to?
A: The UV air sterilizer is used in hospitals, clinics, laboratories, food processing facilities, pharmaceutical manufacturing, offices, schools and public spaces to disinfect air using ultraviolet germicidal irradiation (UV-C, 254 nm) for inactivating bacteria, viruses, fungi and other airborne microorganisms for infection control and contamination prevention. It supports hospital and clinic air disinfection for infection control, laboratory air treatment for biological safety, food processing facility air sanitation, pharmaceutical cleanroom air quality, office and public space air purification, and animal facility air treatment. The UV-C light damages microbial DNA/RNA, preventing reproduction and providing chemical-free air disinfection. It is essential for hospitals, laboratories, food processing, pharmaceutical, office and public space applications requiring UV air disinfection for infection control, contamination prevention, air quality improvement and biological safety, where UV-C germicidal irradiation inactivates airborne bacteria, viruses and microorganisms without chemicals, supporting healthcare infection control, laboratory biosafety, food sanitation, pharmaceutical cleanroom operations and public space air quality improvement in facilities requiring reliable, chemical-free air disinfection capability.
Q2: What standards does the sterilizer comply with?
A: The UV air sterilizer complies with relevant IEC 60335 and IEC 61010 electrical safety standards, applicable GB/T standards for air disinfection equipment, and UV lamp safety standards (IEC 60825, GB 7247 for UV radiation). Medical use follows applicable medical device regulations. UV-C dose should be verified for efficacy. Users should comply with UV radiation safety regulations, including shielding and interlock requirements for occupied spaces.
Q3: What is the warranty period for the whole machine and key components?
A: The whole UV air sterilizer is covered by a 12-month warranty. The UV lamps, chamber, fan, controller and housing are covered, while UV lamps, filters and fuses are consumables or accessories. Damage from improper use, lamp breakage or unauthorized repair is excluded. Extended service contracts may be available.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation is simple: place in the area, set timer or continuous mode, and operate. No professional training is required for basic use, but users should follow UV safety procedures (never expose skin/eyes to UV-C) and maintenance instructions. We provide an operation manual and remote guidance. Proper lamp replacement and cleaning are important for sustained efficacy.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular maintenance required? What is the recommended maintenance cycle?
A: UV lamp replacement every 9-12 months (UV output decreases over time even if lamp is lit). Filter cleaning or replacement per schedule. Lamp and chamber cleaning periodically (dust reduces UV output). Fan and vent condition checked. UV intensity verification annually for critical use. Full system performance check annually.
Q7: Are supporting consumables universal?
A: UV lamps, filters and gaskets are available from specialized suppliers, though lamp type (wavelength, power, base) should match the unit. Long-term consumable cost is low to moderate depending on lamp replacement frequency.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes air flow rate, UV lamp power, room size capacity, filter type (HEPA, activated carbon), control type (timer, sensor, continuous), safety features and accessories. Additional lamps, filters and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the UV air sterilizer and operation manual. On-site installation and training are not included for standard portable units but can be arranged for fixed or ducted systems. Remote guidance is provided.
Q10: What types of environments are compatible with this equipment?
A: The UV air sterilizer disinfects air in rooms, laboratories, food processing areas, healthcare facilities and other spaces within the room size capacity, air flow rate and UV dose specification. The unit should be sized appropriately for the room volume and occupancy. UV-C is harmful to eyes and skin, so units operating in occupied spaces must have proper shielding, interlocks or be upper-room units. Direct exposure units should only operate in unoccupied spaces. Users should never expose skin or eyes to UV-C light, replace lamps per schedule (UV output degrades over time), keep lamps and chambers clean (dust reduces efficacy), use appropriate filters for particulates, ensure proper air circulation, and follow all UV safety regulations. The sterilizer should not be used as the sole infection control measure in high-risk settings; it should complement ventilation, filtration and other infection control practices. For food or pharmaceutical use, the unit should meet applicable regulatory requirements for the facility. The UV lamps contain mercury and should be disposed of per hazardous waste regulations. The unit should be placed for optimal air circulation and UV exposure, and the room size should not exceed the rated capacity for effective disinfection.