Introduction

Auto Chemistry Analyzer is a sophisticated instrument designed to perform biochemical analysis. It automates the analysis, providing accurate and timely results for patient diagnosis and monitoring. Analyzer conducts tests with a high degree of accuracy to assess liver, kidney, lipid, and cardiac function. Excellent detection mechanism guarantees minimal human assistance. Automatic washing function ensures efficiency and prevents cross-contamination between samples.

This chemistry analyzer is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Auto chemistry analyzers play a crucial role in clinical laboratories and other scientific settings including fields like hematology, endocrinology, urinalysis, toxicology, research and development.

Specifications

Throughput 120 tests/hr
Test parameters , , , T-, D-, TP, , , Nh3, , , UA, , γ GT, T-, TG, -C, -C, CK, CK-MB, , , , Anti-, , , D-dimer, HbA1c, RF, , B2M, Cys-C, LP(a), mAIb, MB, ,
Sample volume 2 to 30 µL, 0.1 µL increasing
Reagent volume 20 to 350 µL, 0.1 µL increasing
Analysis methods Kinetic, End point, Fixed Time, Turbidimetry, Absorbance
Sample positions 24 + 5
Calibration position 1
QC position 1
ST position 1
Reagent positions 54 (27 for 6 ml, 27 for 24 ml)
Cuvette positions 81
Wavelength 340, 405, 450, 510, 546, 578, 630,700 nm
Absorbance range 0 to 4.000 Abs
Absorbance precision Inside 0.00001Abs
Repeatability CV <1%
Carry over <0.1%
Water consumption for automatic washing mode 5 L/hr
Water consumption for disposable cuvette mode 2.5 L/hr
Quality control curve x̅, SD, CV%, L-J quality control curve for every test item
Printer Internal thermal sensitive printer
Interface
Power supply 100 to 240 , 50/60 Hz, 100 VA

Features

Disposable cuvette simplifies cleaning process

Open system offers flexibility to choose reagents

Real time curve system monitors and analyzes the chemical reactions

lamp having 10000 hours long life

display improves visualization

Performs liquid level detection

Probe with anticollision function reduce damage

High pressure water flush enhances decontamination

FAQs

1. What are the key factors to consider when selecting this chemistry analyzer for laboratory use?

When selecting this chemistry analyzer, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this chemistry analyzer be calibrated to ensure accurate results?

It is recommended to calibrate this chemistry analyzer at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this chemistry analyzer?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this chemistry analyzer be used with different types of samples, and are there any compatibility considerations?

Yes, this chemistry analyzer can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the chemistry analyzer malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.