Introduction

Horizontal with 150 L capacity and jacket is made of s30408 stainless steel material. Control system to automatically control working of the device and color touch screen display to show working parameters. With safety features like motorized interlock door system, over pressure and over temperature protection.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Horizontal Laboratory Autoclave is widely used in hospitals, pharmaceutical factories, food industries, scientific research institutes and other units to sterilize and dry clothing, dressings, metal instruments, culture medium, etc.

Specifications

Capacity 150 L
Operating temperature 150 ℃
Maximum working temperature 138 ℃
Maximum working pressure 0.25 MPa
Inner chamber operating pressure -0.1 to 0.3 MPa
Jacket operating pressure 0.3 MPa
Opening pressure of inner chamber safety valve 0.28 MPa
Opening pressure of jacketed safety valve 0.28 MPa
Inner chamber hydrostatic test pressure 0.39 MPa
Jacket test pressure 0.52 MPa
Temperature display accuracy 0.1 ℃
Pressure display accuracy 0.1 KPa
Temperature uniformity ± 1 ℃
Time of vacuum pulsation 1 to 99 times
Amplitude of vacuum pulsation ­ 80 to 0 kPa
Number of pulsations Amplitude - 80 to 80 kPa, times 1
Times of positive pressure fluctuation 1 to 3
Ultimate vacuum -97 KPa
Surface temperature ≤ 25 ℃
Steam consumption 12 kg/C
Power 380 V,50 HZ 2 + 24 KW
Tank dimensions (W × D × H) 450 × 800 × 450 mm
Overall dimensions 1160 × 1150 × 1820 mm
Weight 550 kg

Features

150 L volume capacity

Horizontal chamber for efficient loading and unloading of items

Air filter with filtering accuracy of ≤ 0.22 μm

Double door channel type with pressure interlock system

High quality and tear resistant silicone rubber material round hollow door seal ring

Sanitary pipeline ensures a reliable and hygienic seal during the sterilization process

Pneumatic control valve with long life

Water ring vacuum pump with fast pumping speed

Water tank reduces circulating water consumption of vacuum pump

Automatic drainage device ensures steam saturation

Alarm to alert user about over and low temperature and over pressure

FAQs

1. What is the recommended sterilization cycle for different types of laboratory materials?

The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.

2. How to properly load the autoclave to ensure effective sterilization?

Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.

3. What maintenance procedures are required for the autoclave?

Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.

4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?

If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.

5. What safety precautions should be followed when operating the autoclave?

Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.