Introduction

A muffle furnace rated for 950 degrees Celsius is a laboratory furnace used for the heating of the samples to the high temperatures, up to 950 degrees Celsius, and it is used in the materials, the ceramics, the chemistry, the metallurgy, and the many other laboratories. The muffle furnace consists of an insulated heating chamber, the heating elements, a temperature control system with the thermocouple, and the door, and it heats the samples by the electrical heating, providing the controlled high temperatures, with the temperature uniformity; the muffle furnace rated for 950 degrees Celsius is used for the ashing of the organic samples, for the heat treatment, for the gravimetric analysis, for the preparation of the samples, and for many other applications, and it is available in various chamber sizes; the muffle furnace rated for 950 degrees Celsius is an essential equipment for the high-temperature processing. Muffle furnaces rated for 950 degrees Celsius are used in the materials laboratories, in the ceramics industry, in the chemistry laboratories, in the research, and for many other applications. With their high temperatures, muffle furnaces rated for 950 degrees Celsius are essential for the heat treatment.

Muffle Furnace LMF-T2011

Muffle Furnace LMF-T2011



model of Muffle Furnace is uniquely designed with optimum insulation properties and is ideal for ashing of food, plastic and other organic materials. With heating elements Fe-Cr-Al embe...
Muffle Furnace LMF-T2010

Muffle Furnace LMF-T2010



model of Muffle Furnace is uniquely designed with optimum insulation properties and is ideal for ashing of food, plastic and other organic materials. With heating elements Fe-Cr-Al embe...

Standards

IEC 61010-2-010:2020-Particular requirements for laboratory equipment for the heating of materials

Complies with the above standards, but is not limited to them.

Features

1. 950C muffle furnace for routine ashing.

2. Bench furnace reaching 950 degrees C.

3. For ashing, heat treatment and laboratories.

4. Includes furnace, chamber and controls.

5. General-purpose 950C chamber furnace.

FAQ

Q1: What scenarios is this furnace used for?

A: It performs routine ashing, drying and heat treatment up to 950 degrees C for general laboratory work. Customers in related industries rely on it for routine and quality-control work, and we can match the unit to your intended use.

Q2: What standards does it comply with?

A: It follows IEC 61010 and related GB/T standards, with temperature calibrated. Final inspection verifies these parameters before delivery, and the supporting compliance records are available when the order is placed.

Q3: What is the warranty?

A: It carries a 12 to 24 month warranty covering elements and controls. Elements are wear parts. Damage from over-temperature is excluded.

Q4: Is it hard to operate?

A: Operation is simple after training: set a program and run with ventilation. We provide a manual and guidance.

Q5: What is the lead time?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is calibration required?

A: We recommend verification against traceable standards at regular intervals, typically every 6 to 12 months, and keeping calibration records for audit purposes. The manual describes the procedure, and reference standards are available from us. Accredited third-party calibration can also be arranged on request.

Q7: Are consumables universal?

A: Compatible items are single-use consumables designed for this application. They are widely available in standard sizes, and we can supply them directly or confirm the specification so you can source them locally. Ongoing cost is limited to these consumables, and there are no proprietary locked parts.

Q8: Can it be customized?

A: Yes, several configurations are available. Options include chamber size, controllers and exhaust. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.

Q9: Is installation included?

A: No installation is required for this unit. It is ready to run after a simple power connection and the leveling steps shown in the manual. We supply a detailed operation guide and online setup videos, and on-site commissioning can be arranged separately if your facility requires it.

Q10: What samples are compatible?

A: It handles heat-stable samples rated for 950C. It is not for volatile or hazardous contents without venting, sealed containers, or samples exceeding the chamber and temperature.