Introduction
A re-circulating chiller is a refrigeration unit used to provide a circulating fluid at the controlled temperatures, for the cooling of the equipment and the processes, and it is used in the laboratories, the industry, the research, and the many other applications. The re-circulating chiller consists of a refrigeration system with the compressor, the condenser, the evaporator, a circulating pump, a temperature control system, and a reservoir for the circulating fluid, and it cools the fluid and circulates it through the external equipment that requires the cooling, providing a stable and a precise temperature; the re-circulating chiller is used for the cooling of the reaction vessels, for the cooling of the condensers and the traps, for the cooling of the analytical instruments, for the cooling of the lasers, for the temperature control of the processes, and for many other applications, and it is available in various cooling capacities and temperature ranges; the re-circulating chiller provides a reliable and an efficient cooling, and it is an essential equipment for the temperature control. Re-circulating chillers are used in the laboratories, in the chemical and the pharmaceutical industry, in the research, in the semiconductor industry, and for many other applications. With their recirculation, re-circulating chillers are essential for the cooling of the equipment.
Recirculating Chiller T-RCC-C100
Recirculating Chiller T-RCC-C102
Recirculating Chiller T-RCC-C101
Recirculating Chiller T-RCC-L2106
Recirculating Chiller T-RCC-L2104
Recirculating Chiller T-RCC-L2105
Recirculating Chiller T-RCC-L2103
Recirculating Chiller T-RCC-L2102
Re-Circulating Chiller T-RCC-S2101
Standards
AHRI 550/590 (I-P)-2023-Performance Rating of Water-chilling and Heat Pump Water-heating Packages Using the Vapor Compression Cycle
GB/T 18430.1-Water-chilling (heat pump) packages using the vapor compression cycle for industrial and commercial applications
EN 14511-Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors
Complies with the above standards, but is not limited to them.
Features
1. Re-circulating chiller for continuous cooling of laboratory and industrial equipment.
2. Closed-loop circulation provides stable cooling temperature with minimal water waste.
3. Suitable for cooling analytical instruments, reactors, lasers and manufacturing processes.
4. Digital temperature control with pump circulation and alarm functions.
5. Compact design with efficient refrigeration for reliable continuous operation.
FAQ
Q1: What testing scenarios is this chiller mainly applied to?
A: The re-circulating chiller is used in analytical laboratories, research facilities, manufacturing and industrial environments to provide continuous closed-loop cooling for equipment and processes. It supports cooling of analytical instruments such as ICP, mass spectrometers and electron microscopes, jacketed chemical reactors, laser systems, welding equipment, medical devices and industrial manufacturing processes. The closed-loop design eliminates the need for continuous tap water flow, reducing water consumption and providing more stable temperature control than building water systems. It is essential for facilities requiring reliable, consistent cooling for temperature-sensitive equipment and processes where water temperature fluctuations or supply interruptions could affect instrument performance, product quality or process yield.
Q2: What standards does the chiller comply with?
A: The chiller is designed with reference to IEC 61010 laboratory electrical safety standards and relevant GB/T standards for cooling equipment. Performance specifications follow applicable standards for recirculating chillers. Users should verify cooling capacity and temperature range for their specific equipment requirements.
Q3: What is the warranty period for the whole machine and key components?
A: The whole chiller is covered by a 12-month warranty. The compressor, pump, controller and heat exchanger are covered, while coolant and filters are consumables. Damage from improper coolant use, overloading or unauthorized repair is excluded. Extended service contracts are available for critical cooling applications.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires basic training in cooling system setup and maintenance. We provide an operation manual and remote guidance. Proper coolant selection, level maintenance, filter replacement and temperature setting are important for reliable cooling performance.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular maintenance required? What is the recommended maintenance cycle?
A: Coolant level and quality should be checked regularly, with changes according to usage and coolant type. Filters should be cleaned or replaced periodically. Condenser cleaning and pump inspection follow the manufacturer schedule. Temperature calibration is recommended every 6-12 months for critical applications.
Q7: Are supporting consumables universal?
A: Coolant such as water, ethylene glycol or proprietary fluid is available from suppliers, though type should match the temperature range and manufacturer recommendation. Long-term consumable and maintenance cost is moderate depending on usage intensity.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes cooling capacity, temperature range, pump flow and voltage. Additional tubing, filters and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the chiller and accessories with an operation manual. On-site installation and commissioning are recommended for critical cooling systems and can be arranged at additional cost. Remote guidance is provided.
Q10: What types of applications are compatible with this equipment?
A: The chiller provides cooling for compatible equipment and processes within the cooling capacity and temperature range. The equipment being cooled must have compatible heat exchanger connections and heat load. Users should select the appropriate coolant based on the required temperature, ensure proper flow rate and pressure, and avoid operating the pump without coolant. Adequate ventilation should be provided for the chiller condenser to maintain cooling efficiency.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.