Introduction
Low Speed Centrifuge is a compact, tabletop centrifuge, with temperature range of 10 to 80°C and constant temperature control function. Incorporated programmable microprocessor control system, band heater, and fast heating speed with great torque brushless motor, provide maximum speed of 5000 rpm with 4730 × g of maximum . Designed with stainless steel chamber, special skilled centrifugal tubes, and electric lid lock, this centrifuge has 3 phases to keep up the best performance. With big protection and over- temperature protection, this low-speed centrifuge offers fast acceleration and deceleration with ≤60 dBA of low noise.
It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.Applications
Low speed Gerber centrifuge is used to determine the fat content present in milk and other fatty materials using Gerber method across milk and food industry, dairy, biochemistry industry etc.
Specifications
| Maximum speed | 5000 rpm |
| Maximum | 4730 × g |
| Maximum volume | 4×800 ml |
| Timer range | 1 to 99 min |
| Speed accuracy | ±20 rpm |
| Noise | ≤60 dBA |
| Temperature | 10 to 80°C |
| Control system | Programmable microprocessor control system |
| Motor | Brushless motor |
| Display | touch screen |
| Protection | Over-speed and over- temperature protection |
| Lid lock | Electric lid lock |
| Power supply | AC 220 V 50/60 Hz |
| Dimension (L×W×H) | 685 × 500 × 405 mm |
| Net Weight | 67 kg |
| Gross Weight | 95 Kg |
Features
Compact, tabletop Gerber heating (milk fat testing) centrifuge
Temperature range of 10 to 80°C with constant temperature control function
Programmable microprocessor control system, band heater, and fast heating speed
Great torque brushless motor, powder-less and maintenance-free
Maximum speed of 4000 rpm with 2498 × g of maximum
Stainless steel chamber, special skilled centrifugal tubes, and electric lid lock
3 phases to keep up the best performance
Big touch screen, for easy operation and to display different parameters
Over-speed and over- temperature protection
Fast acceleration and deceleration with ≤60 dBA of low noise
High-efficient, stable, safe and reliable
FAQs
1. What is the maximum sample volume that can be processed in the centrifuge?
The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.
2. How to balance the centrifuge before operation?
Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.
3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?
RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.
4. How to maintain the centrifuge to ensure long service life?
Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.
5. What safety precautions should be taken when using the centrifuge?
Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.