Introduction

Air Jacketed CO2 Incubator is a cooling and shaking incubator comprising single orbital platform with triple eccentric shaft balance drive, offers 40 to 300 rpm of speed. Adopted with six sides direct heating, auto-adjustable cycle fan speed, door heating system, and compressor this incubator offers continuous operation within 0 to 5999 min and 4 to 65°C of temperature range. Fluorine-free design with 304 stainless steel chamber, shelves, and platform with round curved corners, it is a load bearing structure provide excellent durability and performance. Equipped with IR sensor, color touch screen controller, password lock function, 90° high temperature and sterilization system, it has unique air duct design. With CO2 concentration sensor, advanced alarm system, temperature control and monitoring system, Micro-biological & filter this incubator ensures controlled, uniform and stable conditions. It provides a stable and controlled environment for cell culture, microbial growth, and other biological experiments. The precise temperature and humidity control ensure consistent experimental conditions and reliable results.

Applications

Air Jacketed CO2 Incubator are used for tissue engineering, cell culture, in vitro fertilization, diagnostics, neuroscience, cancer research and for developing biosensors across medical research, pharmaceutical industry, scientific research, laboratories, etc.

Specifications

CO2 range 0-20%
CO2 recover time (Return to 5% after opening the door for 30 seconds) ≤3 mins
CO2 control accuracy ±0.1%
CO2 stability of 5%CO2 ±0.1%
CO2 uniformity ±0.1%
CO2 sensor IR CO2 sensor
Shaking frequency 40 to 300 rpm
Drive way Three eccentric shaft balance drive type
Humidity control 50 to 90% RH
37°C humidity control accuracy 85% to 95% RH
Humidity resolution 0.001
Humidity deviation ±2%
Allowable shaking load 15 kg
Temperature control range 4 to 65° C
Temperature uniformity ±0.5° C (test point at 37°C)
Ambient temperature 25°C
Heating method 6 side direct heating
Sterilization method 90˚ C moist heat sterilization
Timing range 0 to 5999 min
Platform movement Orbital
Platform size (L×B) 450×450 mm (1pc)
Shelf 3 pcs
Display Colorful touch screen controller
Sterilization system 90° high temp. high humidity sterilization system
Filter Microbiological and filter
Motor Low heat rejection brushless DC motor
Interface RS485
Alarm system Temperature deviation, over temperature, high/low speed, door open, high/low CO2 condensation, disinfection and sterilization reminder, auto cut-off of heat and fan, and auto-stop
Orbital diameter 20 mm+AO2
Interior dimension (W×D×H) 605×700×520 mm
Exterior dimension (W×D×H) 793×975×853 mm
Gross Weight 98 kg (approx.)
Power 1800 W
Voltage 220V 50Hz
Flask Configuration 50 ml×36, 100 ml×23, 250 ml×13, 500 ml×8, 1 L×5, 2 L×3, 4 L×1, 5 L×1

Features

CO2 cooling and shaking incubator with air jacketed configurations

Single orbital platform with triple eccentric shaft balance drive

6 sides direct heating with auto-adjustable cycle fan speed

Door heating system at outer door and large toughened inner glass door for observation

Continuous operation within 0 to 5999 min and 4 to 65°C of temperature range

Fluorine-free design with 304 stainless steel chamber, shelves, and platform with round curved corners

Low heat rejection brushless DC motor with high start torque

CO2 control and monitoring system with IR sensors

Pollution proof control with Micro-biological & filter

90° high temperature and sterilization system for thoroughly sterilization of chamber

Large color touch screen controller with password lock function

Unique air duct design with high quality compressor

Load bearing structure provide excellent durability and performance

Alarm system: Temperature deviation, over temperature, high/low speed, door open, high/low CO2 condensation, disinfection and sterilization reminder, auto cut-off of heat and fan, and auto-stop

High- efficiency, with low power consumption

FAQs

1. How to calibrate the temperature and humidity controls in the laboratory incubator?

Calibration should be performed by qualified personnel using calibrated temperature and humidity sensors: 1) Place the calibrated sensors at different locations inside the incubator chamber to ensure uniform distribution; 2) Set the incubator to the desired temperature and humidity levels and allow it to stabilize for at least 24 hours; 3) Compare the readings from the incubator's display with the calibrated sensors; 4) Adjust the controls according to the manufacturer's instructions if discrepancies are found; 5) Document the calibration results and schedule regular recalibration (every 6-12 months).

2. What is the optimal way to arrange samples inside the incubator for uniform conditions?

To ensure uniform conditions: 1) Avoid overcrowding the incubator, leaving sufficient space between samples for air circulation; 2) Place samples away from the chamber walls, heating/cooling elements, and door to prevent temperature fluctuations; 3) Use shelves or racks that allow air to circulate freely around all samples; 4) Avoid placing large or heat-generating equipment inside the incubator; 5) Rotate samples periodically if long-term incubation is required to account for any minor temperature variations.

3. Can the incubator be used for anaerobic or CO2-enriched environments?

Specialized incubators (anaerobic incubators, CO2 incubators) are designed for these environments. Standard incubators may not maintain the required gas concentrations or oxygen-free conditions. For anaerobic applications, use an incubator equipped with a gas control system that maintains oxygen levels below 1% and may include catalysts to remove oxygen. For CO2-enriched environments, use a CO2 incubator that maintains precise CO2 concentrations (typically 5-10%) and humidity levels, essential for cell culture applications.

4. How to clean and disinfect the incubator to prevent contamination?

Regular cleaning and disinfection steps: 1) Turn off the incubator and allow it to cool down to room temperature; 2) Remove all samples and shelves; 3) Wipe the interior surfaces with a mild detergent solution, followed by a disinfectant compatible with the incubator materials (such as 70% ethanol); 4) For stubborn contamination, use a specialized laboratory disinfectant according to the manufacturer's instructions; 5) Clean the shelves and any accessories separately; 6) Allow all surfaces to dry completely before reassembling and restarting the incubator; 7) Perform this procedure monthly or more frequently if contamination is suspected.

5. What should be done if the incubator temperature fluctuates significantly?

If temperature fluctuations occur: 1) Check if the incubator door is properly closed and sealed; 2) Ensure the incubator is not placed near heat sources, air conditioning vents, or drafty areas; 3) Verify that the incubator is not overloaded, which can restrict air circulation; 4) Check the air filter (if equipped) and replace it if dirty; 5) Inspect the heating and cooling elements for proper operation; 6) If the problem persists, contact technical support for further diagnosis and repair, as it may indicate a malfunction in the temperature control system.