Introduction

Crude Oil Test  Low Speed Centrifuge offers a maximum speed of 4000rpm ensuring efficient separation of impurities from crude oil samples. Its microcomputer control system allows users to modify parameters during operation. The HD large interface for real time monitoring. Its ring-shaped built-in heater provides efficient temperature control and stability. Our Crude Oil Test  Low Speed Centrifuge is suitable for analysis in petroleum refineries, oil fields, and research laboratories.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Crude Oil Test  Low Speed Centrifuge is mainly used for separating water and sediment from crude oil samples to evaluate product purity and quality. It is ideal for petroleum refineries, oil testing laboratories, and research canters performing routine crude oil analysis.

Specifications

Maximum Speed 4000 rpm
Maximum 3881× g
Maximum Capacity 4 × 100ml
Revolutions / min ± 10r/min
Temperature Range Room temperature to +80℃
Timer Range 1 to 99h 59min59s
Voltage VC220 ±22V 50Hz 15A
Power Consumption 850W
Noise Level Less than equal to 65dB
Dimensions 510 × 625 × 405mm
Packaging Dimensions 610 x 750 x 550cm
Net Weight 68 kg
Gross Weight 128 kg

Features

Frequency Conversion Motor

Microcomputer Control System

Temperature Control Function

High Torque Motor

Built-in Ring Heater

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.