Introduction

Triple Quadrupole Gas Chromatograph Mass Spectrometer processes 0.1 µL to 250 µL sample volumes. Equipped with flow rates from 0 to 500 mL/min for N₂ and up to 1000 mL/min for He, H₂. It features a GC inlet reaching 450°C for efficient vaporization of complex compounds. Integrated with mechanical and turbomolecular pumps for consistent charged particle transfer and minimal interference. Gas Chromatograph Mass Spectrometer measures ions from 5 to 1100 amu for diverse analytical procedure.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Triple Quadrupole Gas Chromatograph Mass Spectrometer is essential for identifying polychlorinated biphenyls and nitrophenols in water, banned pesticide residues in Chinese herbal medicines, and various food additives.

Specifications

Working Ambient Temperature 18 to 25 °C
Working Humidity 20 to 60% RH
Pumping Speed 65 m³/h
GC Sample Volume 0.1 µl to 250 µl
Gc Sampling Accuracy ± 0.01%
GC Sampling Precision RSD less than 0.5%
GC Flow Rate 0 to 500 ml/min (N₂), 0 to 1000 ml/min (He, H₂)
GC Inlet Temperature 450 °C
GC Temperature Control Accuracy ± 0.1 °C
GC Pressure Range 0 to 100 psi
GC Pressure Control Accuracy ± 0.001 Psi
GC Heating Rate Up to 120 °C / min, typically 50 °C / min
GC Cooling Rate 5 minutes
GC Pressure Control mode Programmable electronic gas circuit control
MS Mass Analyzer Triple quadrupole mass analyzer
MS Mass Number Range 5 to 1100 amu
MS EI Ion Source Temperature 150 °C to 350 °C
GC-MS Interface Temperature 50 to 400 °C
MS Scan Rate up to 20,000 amu/s
MS Stability less than ± 0.1 amu / 24 hrs.
MS EI Source Ionization Energy 10 eV to 300 eV
MS Resolution 0.4 to 3 amu (adjustable)
MS Detector Pulse counting detectors
MS Sensitivity MRM mode: 100 fg/µL OFN of 1µL, greater than or equal to 15000:1
MS Vacuum Mechanical pump and dual inlet turbo molecular pump
Power Supply 220 ± 20 V AC, 10A, 50 Hz
Dimensions (L × W × H) 1170 × 860 × 860mm
Weight 140 Kg

Features

High Pumping Capacity

Stable EI Ion Source

Tandem QQQ Quality Analyzer

Advanced Thermal Control

Automated Gas Regulation

MRM Mode Sensitivity

Standard Accessories

FAQs

1. What is the main function of this Gas Chromatograph Mass Spectrometer?

It is a professional laboratory instrument designed for Gas Chromatograph Mass Spectrometer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.

2. What are the key advantages of this Gas Chromatograph Mass Spectrometer compared to similar products?

It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.

3. What regular maintenance is required for this Gas Chromatograph Mass Spectrometer?

General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.

4. What are the installation requirements for this Gas Chromatograph Mass Spectrometer?

Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.

5. What should I do if the Gas Chromatograph Mass Spectrometer shows abnormal operation?

General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.