Introduction
Triple Quadrupole Gas Chromatograph Mass Spectrometer processes 0.1 µL to 250 µL sample volumes. Equipped with flow rates from 0 to 500 mL/min for N₂ and up to 1000 mL/min for He, H₂. It features a GC inlet reaching 450°C for efficient vaporization of complex compounds. Integrated with mechanical and turbomolecular pumps for consistent charged particle transfer and minimal interference. Gas Chromatograph Mass Spectrometer measures ions from 5 to 1100 amu for diverse analytical procedure.
Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.
Applications
Triple Quadrupole Gas Chromatograph Mass Spectrometer is essential for identifying polychlorinated biphenyls and nitrophenols in water, banned pesticide residues in Chinese herbal medicines, and various food additives.
Specifications
| Working Ambient Temperature | 18 to 25 °C |
| Working Humidity | 20 to 60% RH |
| Pumping Speed | 65 m³/h |
| GC Sample Volume | 0.1 µl to 250 µl |
| Gc Sampling Accuracy | ± 0.01% |
| GC Sampling Precision | RSD less than 0.5% |
| GC Flow Rate | 0 to 500 ml/min (N₂), 0 to 1000 ml/min (He, H₂) |
| GC Inlet Temperature | 450 °C |
| GC Temperature Control Accuracy | ± 0.1 °C |
| GC Pressure Range | 0 to 100 psi |
| GC Pressure Control Accuracy | ± 0.001 Psi |
| GC Heating Rate | Up to 120 °C / min, typically 50 °C / min |
| GC Cooling Rate | 5 minutes |
| GC Pressure Control mode | Programmable electronic gas circuit control |
| MS Mass Analyzer | Triple quadrupole mass analyzer |
| MS Mass Number Range | 5 to 1100 amu |
| MS EI Ion Source Temperature | 150 °C to 350 °C |
| GC-MS Interface Temperature | 50 to 400 °C |
| MS Scan Rate | up to 20,000 amu/s |
| MS Stability | less than ± 0.1 amu / 24 hrs. |
| MS EI Source Ionization Energy | 10 eV to 300 eV |
| MS Resolution | 0.4 to 3 amu (adjustable) |
| MS Detector | Pulse counting detectors |
| MS Sensitivity | MRM mode: 100 fg/µL OFN of 1µL, greater than or equal to 15000:1 |
| MS Vacuum | Mechanical pump and dual inlet turbo molecular pump |
| Power Supply | 220 ± 20 V AC, 10A, 50 Hz |
| Dimensions (L × W × H) | 1170 × 860 × 860mm |
| Weight | 140 Kg |
Features
High Pumping Capacity
Stable EI Ion Source
Tandem QQQ Quality Analyzer
Advanced Thermal Control
Automated Gas Regulation
MRM Mode Sensitivity
Standard Accessories
FAQs
1. What is the main function of this Gas Chromatograph Mass Spectrometer?
It is a professional laboratory instrument designed for Gas Chromatograph Mass Spectrometer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Gas Chromatograph Mass Spectrometer compared to similar products?
It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.
3. What regular maintenance is required for this Gas Chromatograph Mass Spectrometer?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Gas Chromatograph Mass Spectrometer?
Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.
5. What should I do if the Gas Chromatograph Mass Spectrometer shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.