Introduction
A tabletop autoclave is a compact steam sterilizer designed for benchtop use, used to sterilize laboratory equipment, media, and waste with pressurized steam at high temperature, and it is used in laboratories, clinics, dental and veterinary practices, and small medical facilities. The autoclave consists of a vertical or horizontal cylindrical chamber with a sealed door, a steam generator or a connection to a steam supply, a heating element, a pressure and temperature controller, a digital display, and safety interlocks; in operation, the items to be sterilized are placed in the chamber, the door is closed and sealed, and steam is admitted, raising the temperature and pressure to the sterilization conditions, typically 121 degrees Celsius at about 15 psi, or 134 degrees Celsius for a shorter cycle, and the items are held at the sterilization temperature for a specified time, typically 15-30 minutes, which kills microorganisms, including bacteria, spores, viruses, and fungi, and after the cycle, the steam is exhausted and the chamber is cooled before the items are removed; the tabletop autoclave is compact, easy to operate, and suitable for small workloads, and it is available with features such as automatic cycles, drying, and safety devices. Tabletop autoclaves are used in laboratories for sterilizing culture media, glassware, instruments, and waste, in clinics and dental offices for sterilizing instruments, in veterinary practice, in tattoo and piercing studios, and for many other applications, and they are available in various sizes, with features such as automatic operation, cycle selection, and safety interlocks. With their reliability and convenience, tabletop autoclaves are essential for sterilization in small-scale settings.
Tabletop Autoclave LTTA-T2014
Tabletop Autoclave offers 80 chamber and advanced safety protections. It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, ...
Tabletop Autoclave LTTA-T2010
Tabletop Autoclave offers 20-liter chamber capacity for efficient sterilization in laboratories, clinics, and research facilities. It operates at a temperature range of 105°C to 134°C,...
Tabletop Autoclave LTTA-T2013
Tabletop Autoclave is a portable B-class computer-controlled unit with an accommodation capacity of 35 L for efficient storage. It offers a temperature range of 105 to 134 °C for proper...
Tabletop Autoclave LTTA-T2011
Tabletop Autoclave features a 24-liter capacity, designed for use in laboratories and healthcare settings. Its temperature range of 105°C to 134°C, offers flexibility for diverse steri...
Tabletop Autoclave LTTA-T2011
Tabletop Autoclave is an efficient sterilization unit with a 24-liter stainless steel 304 chamber, ideal for small laboratories. With a 105°C to 134°C range and rapid sterilization, it...
Tabletop Autoclave LTTA-T2010
Tabletop Autoclave features a 20L chamber with three sterilization trays, providing ample space and resistance to corrosion. Operating at a working pressure of 0.22 MPa, it ensures rapid...
Tabletop Autoclave LTTA-T2013
Tabletop Autoclave offers a 50-liter sterilization chamber, delivering efficient sterilization performance. With a rapid sterilization cycle of just 4 to 6 minutes, it provides both spee...
Tabletop Autoclave LTTA-T2012
Tabletop Autoclave features a working pressure of 0.22 MPa and offers a maximum temperature of 134°C. With a programmable sterilization and drying time ranging from 0 to 99 minutes, it ...
Tabletop Autoclave LTTA-T421
Tabletop Autoclave offers a Chamber Volume of 35 mini printer which can record the sterilizer information. Its residual humidity after sterilization is less than 0.2 % for complete dryin...
Table Top Autoclave LTTA-L11
Table Top Autoclave features a 24-liter capacity for efficient performance in clinical, laboratory, and research settings. It operates within a working temperature range of 105°C to 134...
Table Top Autoclave LTTA-L10
Table Top Autoclave features an 18-liter stainless steel chamber, for effective instrument arrangement. With a working temperature range of 105°C to 134°C and a maximum design temperat...
Tabletop Autoclave LTTA-T811
Tabletop Autoclave offers a temperature range of 105°C to 134°C, ensuring consistent sterilization across various applications. It is equipped with advanced a powerful vacuum pump for ...
Tabletop Autoclave LTTA-T810
Tabletop Autoclave offers a 35-liter chamber capacity to meet the stringent demands of laboratories and medical facilities. It features temperature range of 105°C to 134°C, ensuring ef...
Tabletop Autoclave LTTA-T711
Tabletop Autoclave offers a 24 display features a modular interface for simplified operation. Its built-in mini printer records sterilization information for documentation. Our autoclave...
Table Top Autoclave LTTA-T710
Table Top Autoclave features an 18-liter chamber made from high-grade stainless steel 304, ensuring durability and corrosion resistance. It operates at a temperature range of 105°C to 1...
Tabletop Autoclave LTTA-T610
Tabletop Autoclave has a 45L capacity, offering enough space to sterilize various lab instruments and materials. The working temperature ranges from 105°C to 134°C, ensuring effective ...
Tabletop Autoclave LTTA-T611
Tabletop Autoclave has a capacity of 60L, providing ample space for sterilizing a variety of instruments and materials in a single cycle. It operates within a temperature range of 105°C...
Tabletop Autoclave LTTA-T517
Tabletop Autoclave chamber size of Ø250 × 470 mm for handling various sterilization loads efficiently. Its efficient air release function ensures optimal sterilization by eliminating r...
Tabletop Autoclave LTTA-T516
Tabletop Autoclave chamber volume of Ø250 × 370 mm offers optimal space for efficient sterilization. Its refill-friendly water access simplifies maintenance and usage. The triple-layer...
Tabletop Autoclave LTTA-T515
Tabletop Autoclave has a size of Ø200 × 355 mm for sterilizing small to medium-sized instruments. It features an audible cycle completion alert for convenience. The instant steam gener...
Tabletop Autoclave LTTA-T514
Tabletop Autoclave has a size of Φ 250 x 452 mm for efficiently sterilizing small instruments and labware. It features an intelligent locking mechanism that ensures secure operation dur...
Tabletop Autoclave LTTA-T513
Tabletop Autoclave capacity of 23 safety mechanism ensures user and equipment protection throughout the cycle. The end-of-cycle notification provides timely alerts, enhancing operational...
Tabletop Autoclave LTTA-T512
Tabletop Autoclave has a capacity of 18 laboratory and clinical operations. It features dual temperature modes that offer flexibility for different sterilization needs. The fully automat...
Tabletop Autoclave LTTA-T511
Tabletop Autoclave has a 35 sterilization for accurate temperature and time settings. The advanced safety interlock system prevents the lid from opening mid-cycle. Its user-friendly touc...
Tabletop Autoclave LTTA-T510
Tabletop Autoclave has a capacity of 8 use and prevents external contamination. Its customizable temperature settings allow users to tailor sterilization cycles based on specific needs. ...
Table Top Autoclave LTTA-T420
Table Top Autoclave offers a 50L capacity with a maximum working temperature of 134℃ ±1℃. It uses saturated steam to disinfect objects, ensuring a thorough and effective sterilization...
Tabletop Autoclave LTTA-T320
Tabletop Autoclave offers a chamber volume of 23 facilities. It can precisely control temperature ramping with at least two ramps. The unit displays the temperature ramping schedule as a...
Tabletop Autoclave LTTA-T410
Tabletop Autoclave offers an 18L capacity and operates at a maximum temperature of 134°C. Constructed with a durable stainless steel inner tank and a sealed cover, it ensures long-lasti...
Tabletop Autoclave LTTA-T2014
Tabletop Autoclave is a portable B-class computer-controlled unit with a temperature range of 105 to 134 °C for proper sterilization. It offers an accommodation capacity of 50 L for eff...
Tabletop Autoclave LTTA-T310
Tabletop Autoclave features a 35L capacity and supports sterilizing temperatures from 55℃ to 134℃, ideal for a wide range of applications. It uses multiple pulse-vacuum cycles for effe...
Tabletop Autoclave LTTA-T2020
Tabletop Autoclave is a durable, top-loading sterilizer with a 134°C sterilization temperature. It offers a camber capacity of 24 inner circulation system with steam discharge, ensuring...
Tabletop Autoclave LTTA-T2013
Tabletop Autoclave offers 50-liter chamber capacity for reliable and efficient sterilization. It operates at a temperature range from 105°C to 134°C, suitable for sterilizing various i...
Tabletop Autoclave LTTA-T2012
Tabletop Autoclave features a chamber capacity of 35L, maintaining a small footprint. It operates at a working pressure of 0.22 MPa and reaches a maximum temperature of 134°C. It featur...
Tabletop Autoclave LTTA-T2010
Tabletop Autoclave is a space-saving unit with a capacity of 20 liters. It has a sterilization temperature of 134°C for effective sterilization processes. Equipped with advanced safety ...
Tabletop Autoclave LTTA-T2011
Tabletop Autoclave is a space-saving unit with a capacity of 35 liters. It has a sterilization temperature of 134°C for effective sterilization processes. Equipped with advanced safety ...
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
Complies with the above standards, but is not limited to them.
Features
1. Table top autoclave for compact steam sterilization of laboratory instruments and media.
2. Pressure steam sterilization with programmable cycles for laboratory and clinical use.
3. Suitable for laboratories, clinics, dental, veterinary, educational and research facilities.
4. Includes pressure chamber, heating system, controller, safety valves and operation manual.
5. Supports reliable sterilization of glassware, media, instruments and biological waste.
FAQ
Q1: What testing scenarios is this autoclave mainly applied to?
A: The table top autoclave is used in research laboratories, clinical facilities, dental clinics, veterinary practices, educational institutions, pharmaceutical labs and microbiology labs to sterilize laboratory instruments, glassware, culture media, biological waste and other heat-stable items using pressurized steam at 121 degrees C or 134 degrees C for infection control, laboratory safety and regulatory compliance. It supports laboratory glassware and instrument sterilization (beakers, flasks, pipettes, tools), culture media preparation and sterilization (agar, broth, media bottles), biological waste decontamination (cultures, contaminated materials, biohazard waste), dental instrument sterilization, veterinary clinic equipment sterilization, clinical laboratory consumable sterilization, and educational laboratory use. The compact table top design provides reliable steam sterilization for facilities with lower volume needs or limited space, ensuring proper infection control and laboratory safety.
Q2: What standards does the autoclave comply with?
A: The table top autoclave follows relevant ISO, ASTM, EN and GB/T standards for steam sterilizers, including ISO 17665 (sterilization of health care products by moist heat), EN 13060 (small steam sterilizers), ASTM E1008, and relevant GB/T standards including GB 15981 (disinfection and sterilization) and YY 1007 (vertical pressure steam sterilizers). The hardware complies with applicable pressure vessel standards (ASME, GB 150) and IEC 61010 safety standards. Sterilization efficacy should be verified with biological indicators (Geobacillus stearothermophilus spores) per standard. For clinical use, follow applicable medical device regulations (FDA, CE, NMPA). Users should verify the specific class (N, S, B per EN 13060) based on load type.
Q3: What is the warranty period for the whole autoclave and key components?
A: The whole table top autoclave is covered by a 12-month warranty. The pressure chamber, heating system, controller, safety valves and housing are covered, while seals, gaskets, filters and fuses are consumables or accessories. Damage from improper use, overpressure, chamber damage or unauthorized repair is excluded. Extended service contracts may be available. Pressure chamber may have separate warranty terms (typically 5-10 years for stainless steel chamber).
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained personnel familiar with autoclave operation, steam sterilization and safety. We provide operation manuals, training and application support. Proper loading (do not overload, allow steam penetration), cycle selection (121 degrees C/15 psi for general, 134 degrees C for wrapped/instruments), water quality (use distilled or deionized water to prevent mineral buildup), biological indicator testing, maintenance (seal/gasket inspection, chamber cleaning), safety procedures (pressure release, hot steam burns) and regulatory documentation are important for safe, effective sterilization.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Sterilization efficacy verification with biological indicators (Geobacillus stearothermophilus) recommended weekly or per load for critical use, at minimum monthly. Temperature and pressure calibration every 6-12 months. Routine monitoring per cycle (temperature, pressure, time). Safety valve testing per schedule. Seal/gasket inspection regularly (replace when worn or cracked). Chamber cleaning and descaling per schedule (depends on water quality). Full autoclave performance verification annually. Door seal/latch inspection.
Q7: Are supporting consumables universal?
A: Seals/gaskets, filters, biological indicators, chemical indicators, autoclave tape, cleaning/descaling solutions and fuses are available from laboratory suppliers, though seal/gasket size should match the autoclave model. Long-term consumable cost includes distilled/deionized water (continuous use) and biological/chemical indicators (per test schedule).
Q8: Can I customize parameters or supporting accessories?
A: Customization includes chamber capacity (volume, typically 12-150 liters), sterilization class (N, S, B per EN 13060), temperature range (105-138 degrees C), cycle programs (number of pre-set cycles, custom cycles), drying capability (for wrapped instruments), data logging, printer, connectivity, safety features and accessories. Additional trays, racks, bags and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the table top autoclave and accessories with an operation manual. On-site installation, calibration and training are not included for standard orders but can be arranged at additional cost (recommended for clinical use). Remote guidance is provided.
Q10: What types of items are compatible with this equipment?
A: The table top autoclave sterilizes heat-stable, moisture-stable items including glassware (beakers, flasks, pipettes, bottles), stainless steel instruments (surgical, dental, laboratory tools), culture media (agar, broth, media in bottles/tubes - use vented caps or loose caps to allow steam penetration), biological waste (cultures, contaminated plates, biohazard bags - use proper biohazard bags, do not seal tightly), clothing/linen (lab coats, towels - if class B/S), wrapped instrument packs (if class B with pre-vacuum), and other heat-stable items within the chamber capacity, temperature and pressure specification. Items that should NOT be autoclaved: plastics that melt at 121 degrees C (use only polypropylene, PMP, PTFE rated for autoclaving - check manufacturer rating), volatile or flammable chemicals (can explode or ignite), radioactive materials (follow specific radiation safety procedures), items with residual organic solvents (can cause explosion), sealed containers (pressure buildup can cause explosion - loosen caps or use vented containers), and items that cannot withstand steam/moisture (some electronics, optical components, certain adhesives). Users should follow the specific sterilization cycle for the load type (121 degrees C/15 psi for 15-30 minutes for general unwrapped items, 134 degrees C/30 psi for 3-4 minutes for wrapped instruments if class B, longer cycles for large or dense loads), load the chamber properly (do not overload - leave space for steam circulation, do not block steam vents, place items with openings facing down or sideways for drainage), use appropriate containers (autoclave-rated polypropylene, glass, stainless steel - loosen caps or use vented caps for media bottles), use distilled or deionized water (tap water causes mineral buildup in chamber and heating element, reducing efficiency and lifespan - use only distilled/deionized water, check water level before each run), verify sterilization with biological indicators (Geobacillus stearothermophilus spores - place in the most challenging location in the load, e.g., center of a large pack or bottom of chamber), use chemical indicators (autoclave tape, indicator strips) on each pack for visual confirmation, allow proper cooling before opening (chamber and contents are hot and under pressure - wait until pressure reaches zero and temperature below 80 degrees C before opening, use heat-resistant gloves), dry items properly (especially wrapped instruments - use drying cycle if available, or allow to dry in a clean area), and for clinical/regulated use, maintain proper documentation (cycle logs, biological indicator results, maintenance records per GMP/GLP/ISO). The autoclave should be placed on a stable, heat-resistant, level surface with proper clearance (do not place against wall - need ventilation for steam exhaust and condenser; do not place under cabinets that can be damaged by steam). The chamber should be cleaned regularly (remove trays, wipe chamber with mild detergent, rinse, dry - remove mineral deposits with descaling solution if using tap water; always use distilled water to minimize this). The door seal/gasket should be inspected regularly (cracks, wear, deformation - replace if damaged; a faulty seal causes steam leaks and incomplete sterilization). The safety valve should be tested per schedule (verify it releases at the correct pressure - do not override or block the safety valve). The autoclave should NOT be operated without water (can burn out the heating element and cause fire - always check water level before starting a cycle). For media sterilization, use liquid cycle (slower heating/cooling to prevent boil-over) and do not fill bottles more than 2/3 full (liquid expands when heated and can boil over). For biological waste, use proper biohazard bags and do not overfill (leave room for steam penetration; seal bags loosely or use autoclave bags with indicator). Waste (used biological indicators, chemical indicators, autoclave waste) should be disposed of per applicable regulations (biohazard waste after sterilization may be disposed as regular waste in some jurisdictions, but verify local regulations).
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.