Introduction
Tabletop Autoclave has a capacity of 8 use and prevents external contamination. Its customizable temperature settings allow users to tailor sterilization cycles based on specific needs. The smart sterilization cycle control provides precision in temperature regulation for effective decontamination. Our tabletop autoclave has an integrated diagnostic port that enables easy system monitoring.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Tabletop Autoclave is a compact sterilization unit that uses pressurized steam to disinfect medical and laboratory tools efficiently. It is widely used in clinics, dental offices, and research labs for quick and reliable sterilization of small instruments and glassware.
Specifications
| Capacity | 8 L |
| Chamber Size | Ø170 × 320 mm |
| Working Sterilization Temperature | 134℃ |
| Working Sterilization Pressure | 0.22 Mpa |
| Design Pressure | 0.25 Mpa (2.5 bar) |
| Design Temperature | 139℃ |
| Working Pressure | 0.22 Mpa (2.2 bar) |
| Voltage | 110 V/220 V,60 Hz/50 Hz |
| Power Consumption | 1.5 kW |
| Outer Dimension (L × W × H) | 445 × 580 × 400 mm |
| Packing Dimension (L × W × H) | 650 × 500 × 450 mm |
| Gross Weight | 45 kg |
| Net Weight | 42 kg |
Features
Microcomputer Controlled Sterilization
Advanced Safety Interlock System
User-Friendly Touch Controls
Standard Test Interface Equipped
Top-Fill Water Tank
FAQs
1. How does a tabletop autoclave differ from a vertical or horizontal autoclave?
It tabletop autoclaves are primarily designed for low to medium-capacity sterilization needs, unlike vertical or horizontal autoclaves which are often used for high-volume or industrial applications. While the underlying principle of steam sterilization remains the same, tabletop models are more portable, energy-efficient, and space-saving. They are typically placed on benchtops, require less installation effort, and are ideal for routine use. They also consume less water and power, making them a more cost-effective solution for smaller laboratories or clinics that don’t require bulk sterilization.
2. Are tabletop autoclaves suitable for sterilizing wrapped or packaged instruments?
It tabletop autoclaves are equipped with pre-vacuum and drying phases, allowing them to effectively sterilize wrapped or packaged instruments, which is essential for maintaining sterility until the items are used. These features help remove air pockets from both the chamber and the packaging, ensuring even steam penetration. The drying cycle uses residual chamber heat and vacuum to eliminate moisture, which prevents the re-growth of microorganisms. This makes them suitable for dental tools, surgical instruments, reusable lab kits, and any item that needs to be stored sterile for later use.
3. How user-friendly are tabletop autoclaves for daily operation?
It designs its tabletop autoclaves to be highly user-friendly, even for non-technical staff. They feature touchscreen digital displays or button-operated panels, with pre-programmed cycles for different types of loads (e.g., solids, liquids, wrapped instruments). models include automated functions like water filling, steam generation, pressure release, and drying, which minimize manual intervention and reduce error. Users are guided through each step of the sterilization process with visual and audio cues, and error messages are clearly displayed for troubleshooting. This ease of operation increases efficiency and helps maintain consistent sterilization standards across all users.
4. How much maintenance does a tabletop autoclave require?
It tabletop autoclaves are engineered for low-maintenance operation, but regular care is crucial to ensure consistent performance and long service life. Routine maintenance includes checking the water reservoir, cleaning the chamber, inspecting door gaskets, descaling the heating elements, and ensuring the drainage system is clear. The control system usually provides service reminders or alerts for maintenance intervals. It also provides a detailed user manual and preventive maintenance schedule, making upkeep simple even for first-time users.
5. Are tabletop autoclaves energy and water-efficient?
It designs its tabletop autoclaves to be highly efficient in both water and power consumption. Modern models use microprocessor-based systems to optimize steam generation and regulate energy usage, reducing operational costs over time. The autoclaves are also equipped with automatic water usage control and shut-off features, preventing wastage and ensuring safe operation. These efficiency features make them ideal for facilities looking to reduce their ecological footprint without compromising sterilization quality.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.