Introduction
Tabletop Autoclave features a working pressure of 0.22 MPa and offers a maximum temperature of 134°C. With a programmable sterilization and drying time ranging from 0 to 99 minutes, it ensures both speed and precision. Its microcomputer control system and digital display make operation intuitive. In addition, its wide voltage compatibility ensures ease of installation in various environments.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Our Tabletop Autoclave is ideally suited for sterilizing surgical instruments, laboratory glassware, and other heat-resistant medical and scientific equipment.
Specifications
| Capacity | 35 L |
| Maximum Working Pressure | 0.23 MPa |
| Working Pressure | 0.22 MPa |
| Working Temperature | 134°C |
| Working Temperature Range | 105°C to 134°C |
| Sterilization Program | 3 preset programs + user-defined program |
| Rapid Sterilization Time | 4 to 6 minutes |
| Sterilization Time Range | 0 to 99 minutes |
| Drying Time Range | 0 to 99 minutes |
| Temperature Accuracy | ±0.1°C |
| Heat Distribution Uniformity | ≤1°C |
| Control System | Microcomputer |
| Display Type | Digital Display |
| Indicator | Digital Display Type |
| Steam Generator Material | Stainless Steel 304 |
| Chamber Material | Stainless Steel 304 |
| Door Type | Safety Interlock Door |
| Drying System | Available |
| Loading Tray | Removable, Stainless Steel |
| Voltage | 110 to 220V, 50/60Hz |
| Power Consumption | 2.7 kW |
| Chamber Volume | 35L / Ø300 × 500 mm |
| Product Dimensions (L × W × H) | 730 × 550 × 540 mm |
| Package Dimensions (L × W × H) | 810 × 680 × 700 mm |
| Net Weight | 75 kg |
| Gross Weight | 95 kg |
Features
High Sterilization Efficiency
Programmable Settings
Wide Temperature Range
Precise Temperature Control
User-Friendly Interface
Durable Construction
Integrated Drying System
Safety Features
Removable Tray
Compact Design
Wide Voltage Compatibility
FAQs
1. What are the key features of the Tabletop Autoclave that make it suitable for clinical and laboratory environments?
The Tabletop Autoclave is equipped with a range of advanced features that make it ideal for use in clinics, laboratories, dental practices, and hospitals. It offers a high working temperature of 134°C and operates under a working pressure of 0.22 MPa, ensuring effective sterilization of instruments. It includes three preset programs along with a user-defined program for flexibility, and its rapid sterilization cycle of 4–6 minutes is ideal for busy facilities. The unit also features a precise temperature accuracy of ±0.1°C, stainless steel 304 chamber and steam generator, a digital display, and a microcomputer control system for easy and safe operation.
2. How does the Tabletop Autoclave ensure effective and uniform sterilization across all loads?
The Tabletop Autoclave ensures consistent sterilization with a heat distribution uniformity of less than equal to 1°C and precise temperature control. Its stainless steel 304 chamber and built-in steam generator provide a stable environment for thorough sterilization. Additionally, its programmable sterilization and drying times (0 to 99 minutes) allow users to adjust settings based on load type, ensuring that even complex instruments receive complete exposure to steam and heat.
3. Can the Tabletop Autoclave handle different types of medical and laboratory instruments?
Yes, the Tabletop Autoclave is designed with versatility in mind. It includes a removable stainless steel sterilization tray that accommodates a wide variety of instruments, including surgical tools, dental handpieces, laboratory glassware, and metal items. Its wide temperature range (105°C to 134°C) and customizable programs allow it to sterilize both delicate and heavy-duty items effectively.
4. What safety features are incorporated in the Tabletop Autoclave for operator protection?
The Tabletop Autoclave includes several safety mechanisms to protect users and maintain equipment integrity. A key feature is its safety interlock door, which prevents the door from opening while the chamber is pressurized or during sterilization cycles. The microcomputer control system continuously monitors the operation, and the digital display provides real-time status updates, helping operators manage sterilization tasks safely and efficiently.
5. How does the Tabletop Autoclave support efficient workflow in high-demand environments?
With a chamber volume of 35 liters and a rapid sterilization cycle of just 4 to 6 minutes, the helps maintain a smooth and uninterrupted workflow, especially in high-throughput settings like hospitals and labs. Its programmable drying time and preset cycles reduce manual intervention and downtime. Additionally, the compact footprint (730×550×540 mm) allows it to be placed easily on standard countertops, conserving space without sacrificing performance.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.