Introduction
Atomic Absorption Spectrophotometer provides detection limit of Cu less than 0.006µg/ml. Built with dual atomization modes, it supports both flame and graphite furnace analysis. Incorporates single-beam optical system for reliable signal measurement. Offers D2 and self-absorption background correction for enhanced performance. Spectrophotometer features multiple safety sensors, including gas flow, pressure, and furnace monitoring.
Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.
Applications
Atomic Absorption Spectrophotometer is suitable for both high-concentration and ultra-trace detection. It is employed in petrochemistry, metallurgy, mining, geology, material analysis, food and pharmacy.
Specifications
| Optical Type | Single beam |
| Atomizer | Flame and Graphite furnace |
| Monochromator | Czerny-Turner type, focal length at 350mm |
| Wavelength Range | 190 to 900 nm |
| Wavelength Accuracy | ±0.2nm |
| Wavelength Repeatability | ±0.1nm |
| Grating | Holographic diffraction grating with 1800 lines/mm |
| Slits | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0nm |
| Lamp Holder | Automated 8 lamp turret |
| Detector | Wide range UV-sensitive photomultiplier tube |
| Reading Mode | Transmittance(T), Absorbance(A), Concentration(C) |
| Photometric Range | 0 to 125%, -0.1 to 3.00A |
| Static Baseline Drift (Cu) | Less than 0.003A/30 min |
| Dynamic Baseline Drift | Less than 0.005A/15min |
| Background Correction | D2 and self-absorption |
| Characteristic Concentration | Cu less than 0.035µg/ml |
| Characteristic Mass | Cd less than 0.8pg, Cu less than 20pg |
| Detection Limit | Flame Analysis: Cu less than 0.006µg/ml, |
| Repeatability (Cu) | Flame Analysis: RSD less than 0.6%, |
| Acetylene Flow Control | Auto 12-level |
| Air Flow Control | Auto 4-level |
| Burner Head | 100mm Titanium alloy burner |
| Ambient Temperature | 3000°C |
| Ramp And Holding Time | 1 to 255s |
| Heating Rate | Maximum linear heating rate 2000°C/s |
| Heating Method | Light-controlled heating, Time-controlled heating, General heating |
| Gas Flow Rate Inside Tube | 1L/min |
| Gas Flow Rate Outside Tube | 0, 50, 200, 250ml/min |
| Safety Protection | Water flow sensor, Argon pressure sensor, Furnace body temperature sensor, Graphite tube installation self-inspection, Flame sensor, Gas leak sensor, Gas pressure sensor |
| Software | RGWIN AAS software package |
| Analytical Method | Flame AA, Flame AE, Hydride generation |
| Concentration Calculation Method | Standard curve, Standard Addition, Interpolation |
| Repeated Measurement Times | 1-30 times, Average, SD and RSD |
| Qa/Qc Function | Correlation coefficient, SD & RSD |
| Communication Port | Standard RS-232 |
| Working Environment | Temperature 10-35 °C, Humidity less than 85% |
| Power Supply | 110/220V, 50/60Hz |
| Dimension(W×D×H) | 850×650×550mm |
| Weight | 100KG |
Features
Speed-adjustable external gas flow rate
Automated slit selection
High-efficiency glass nebulizer
Automatic up and down burner adjustment
Corrosion-resistant premix chamber
Parameter and result printing
Standard Accessories
FAQs
1. What is the main function of this Atomic Absorption Spectrophotometer?
It is a professional laboratory instrument designed for Atomic Absorption Spectrophotometer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Atomic Absorption Spectrophotometer compared to similar products?
It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.
3. What regular maintenance is required for this Atomic Absorption Spectrophotometer?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Atomic Absorption Spectrophotometer?
Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.
5. What should I do if the Atomic Absorption Spectrophotometer shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.