Introduction

A stainless steel fume hood is a laboratory fume hood made of the stainless steel, with a ventilation system, used for the containment and the removal of the hazardous fumes, the vapors, and the particles, and it is used in the chemistry, the biology, the pharmaceutical, and the industrial laboratories, particularly for the applications that require a durable and a corrosion-resistant work surface. The stainless steel fume hood consists of a work chamber with a transparent sash, a work surface made of the stainless steel, an exhaust system with a duct and a blower, and a control system, and it is used for the performance of the procedures that generate the hazardous fumes, such as the digestion, the evaporation, the synthesis, and the handling of the volatile and the corrosive chemicals, and it provides the containment and the exhaust of the fumes, protecting the operator and the environment; the stainless steel construction provides a durable and a corrosion-resistant surface, which is easy to clean, and it is suitable for the applications that require a clean and a sterile environment, and the stainless steel fume hood is available in various sizes, from the bench-top models to the floor-standing models, and it may include features such as the airflow monitoring, the lighting, and the services, such as the water, the gas, and the electrical connections; the stainless steel fume hood is an essential safety equipment in the laboratories. Stainless steel fume hoods are used in the chemistry and the biology laboratories, in the pharmaceutical laboratories, in the food testing, in the research institutions, and for many other applications. With their durable construction and the fume containment, stainless steel fume hoods are essential for the safe handling of the hazardous materials.

Stainless Steel Fume Hood LSFH-T2011

Stainless Steel Fume Hood LSFH-T2011



Stainless Steel Fume Hood has an internal dimension of 1250 × 700 × 1150 mm ensuring sufficient space for experimental procedures. With 304 Stainless Steel worktop, it provides excelle...
Stainless Steel Fume Hood LSFH-T2010

Stainless Steel Fume Hood LSFH-T2010



Stainless Steel Fume Hood features work surface height of 800 mm ensures ergonomic comfort and efficient workflow. Equipped with efficient air filtration systems for safe and controlled ...

Standards

ASHRAE 110-Method of Testing Performance of Laboratory Fume Hoods

Complies with the above standards, but is not limited to them.

Features

1. Stainless steel fume hood for chemical fume extraction.

2. Stainless hood with sash, baffle, exhaust and work surface.

3. For chemical, pharmaceutical and clean laboratories.

4. Includes hood, sash, lighting, exhaust connection and manual.

5. Protects users from hazardous fumes with controlled airflow.

FAQ

Q1: What scenarios is this fume hood used for?

A: It contains and exhausts hazardous chemical vapors and aerosols during laboratory work, protecting the user through controlled face velocity and a sash, with stainless construction for chemical or clean environments.

Q2: What standards does it comply with?

A: It follows ANSI/AIHA Z9.5, EN 14175, ASHRAE 110 containment testing and related GB/T standards, with face velocity verified after installation.

Q3: What is the warranty?

A: The hood carries a 12 to 24 month warranty covering the cabinet, sash and lighting. Ductwork and fans are separate or site-specific. Damage from corrosion or modification is excluded.

Q4: Is it hard to operate?

A: Use requires training on sash position, airflow and chemical compatibility. We provide a manual and guidance.

Q5: What is the lead time?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is calibration required?

A: Verify face velocity and containment periodically, including ASHRAE 110 after installation. Keep airflow test records.

Q7: Are consumables universal?

A: Airflow monitors and filters are hood-specific, while lighting is standard. Ongoing cost includes monitoring and service.

Q8: Can it be customized?

A: Yes, several configurations are available. Options include width, stainless grade, sash type, airflow monitors, explosion-proof fittings and ductwork. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.

Q9: Is installation included?

A: Standard delivery includes the hood and manual. Ducting, fans and electrical work are site-specific, with installation and containment testing arranged.

Q10: What chemicals are compatible?

A: It handles chemicals compatible with stainless and within the hood design. It is not for perchloric acid without a dedicated wash-down hood, radioisotopes without special hoods, or processes beyond airflow containment.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry