Introduction

Atomic Absorption Spectrophotometer features czerny-turner monochromator with 350mm focal length. Equipped high-sensitivity system, it ensures superior detection limit for trace element analysis. Incorporates multiple reading modes, supporting absorbance and transmittance measurements. Integrated with advanced heating methods for controlled temperature management. Spectrophotometer offers safety functions, including water flow, argon pressure, and furnace heat sensors.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Atomic Absorption Spectrophotometer is employed in quantification of trace metal elements in environmental samples, biological fluids, pharmaceuticals, food, metallurgy, forensic evidence, geological materials, and agricultural products.

Specifications

Optical Type Single beam
Atomizer Graphite furnace
Monochromator Czerny-Turner type, focal length at 350mm
Wavelength Range 190 to 900 nm
Wavelength Accuracy ±0.2nm
Wavelength Repeatability ±0.1nm
Grating Holographic diffraction grating with 1800 lines/mm
Slits 0.1, 0.2, 0.4, 0.7, 1.4, 2.0nm
Lamp Holder Automated 8 lamp turret
Detector Wide range UV-sensitive photomultiplier tube
Reading Mode Transmittance(T), Absorbance(A), Concentration(C)
Photometric Range 0 to 125%, -0.1 to 3.00A
Static Baseline Drift (Cu) Less than 0.003A/30 min
Dynamic Baseline Drift Less than 0.005A/15min
Background Correction Deuterium background correction
Characteristic Mass Cd less than 0.8pg, Cu less than 20pg
Detection Limit Cd less than 1pg, Cu less than 10pg
Repeatability (Cu) RSD less than 4%
Ambient Temperature 3000oC
Ramp And Holding Time 1 to 255s
Heating Rate Maximum linear heating rate 2000oC/s
Heating Method Light-controlled heating, Time-controlled heating, General heating
Gas Flow Rate Inside Tube 1L/min
Gas Flow Rate Outside Tube 0, 50, 200, 250ml/min
Safety Protection Water flow sensor, Argon pressure sensor, Furnace body temperature sensor, Graphite tube installation self-inspection
Software RGWIN AAS software package
Analytical Method Flame AA, Flame AE, Hydride generation
Concentration Calculation Method Standard curve, Standard Addition, Interpolation
Repeated Measurement Times 1-30 times, Average, SD and RSD
Qa/Qc Function Correlation coefficient, SD & RSD
Communication Port Standard RS-232
Working Environment Temperature 10-35 °C, Humidity less than 85%
Power Supply 110/220V, 50/60Hz
Dimension(W×D×H) 850×650×550mm
Weight 100KG

Features

Speed-adjustable external gas flow rate

Automated slit selection 

3600 Rotating 8-lamp turret

Deuterium background correction

Parameter and result printing

Graphite tube installation self-inspection

Standard Accessories

FAQs

1. What is the main function of this Atomic Absorption Spectrophotometer?

It is a professional laboratory instrument designed for Atomic Absorption Spectrophotometer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.

2. What are the key advantages of this Atomic Absorption Spectrophotometer compared to similar products?

It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.

3. What regular maintenance is required for this Atomic Absorption Spectrophotometer?

General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.

4. What are the installation requirements for this Atomic Absorption Spectrophotometer?

Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.

5. What should I do if the Atomic Absorption Spectrophotometer shows abnormal operation?

General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.