Introduction
Automatic Electrolyte Analyzer measures Na⁺, K⁺ and Cl⁻ with high accuracy and fast analysis speed. Equipped with sample tray that allows convenient and efficient sample handling. Incorporated with real-time monitoring and automatic calibration for consistent performance. It includes LCD display, built-in thermal printer, and user-friendly interface. Analyzer is widely used in hospitals, clinics, and laboratories for rapid electrolyte testing.
Calibrated according to national metrology standards, ensuring measurement accuracy and traceability. The instrument has passed CE certification, suitable for use in international markets.
Applications
Automatic Electrolyte Analyzer is applied in clinical laboratories and hospitals for rapid electrolyte measurement in serum, plasma, and whole blood samples. It is widely employed for patient diagnosis, treatment monitoring, and critical care analysis.
Selection Guide
Automatic Electrolyte Analyzer is a versatile and research-grade instrument suitable for laboratories involved in clinical diagnostics, biomedical research, and healthcare studies. It employs the Ion Selective Electrode (ISE) method, which is widely recognized for its accuracy and reliability in measuring electrolytes. This model supports a broad range of sample types, including serum, plasma, whole blood, cerebrospinal fluid (CSF), and diluted fluids, making it suitable for diverse research and clinical applications. With a capacity to handle up to 35 sample positions and a flexible sample volume range of 60 to 300 µl, it enhances throughput and operational efficiency. Its certifications and compliance with clinical laboratory standards ensure data accuracy and repeatability, which are critical for research experiments and routine patient diagnostics. This makes it a suitable choice for labs requiring accurate, multi-sample electrolyte analysis across varied biological matrices.
Specifications
| Sample Type | Serum, plasma, whole blood, cerebrospinal fluid and dilute urine |
| Test Parameters | Na⁺, K⁺, Cl⁻ |
| Measuring Range | Na⁺: 20 to 200 mmol/L, K⁺: 1 to 10 mmol/L, Cl⁻: 10 to 150 mmol/L |
| Resolution | 0.01 mmol/L |
| Measuring Speed | Less than or equal to 25s |
| Analysis Method | Ion Selective electrode |
| Sample Volume | 60 to 150 µl |
| Sample Position | 30 sample position, 5 emergency position |
| Injection Mode | Manual or automatic injection can be selected |
| Storage | Up to 50,000 test results |
| Printer | Built-in thermal printer |
| Interface | RS232 |
| Display | 7-inch high-definition touchscreen |
| Calibration | Automatic and manual calibration |
| Atmospheric Pressure Range | 86 to 106 kPa |
| Temperature Range | 10 to 40ºC |
| Relative Humidity | Less than or equal to 80% |
| Sample Tray | Yes |
| Power Supply | AC 100 to 240V, 50 to 60Hz |
| External Dimensions | 682×287×471 mm |
| Packaging Dimensions | 500×390×720 mm |
| Net Weight | 15.11 Kg |
| Gross Weight | 19.31 Kg |
| Repeatability | ≤2% RSD |
Features
Power-off protection
Equipped with RS232/USB communication interface for data export and remote control. Supports connection to laboratory information management system (LIMS) for centralized data management and traceability.
7-inch high-definition touchscreen
Automatic fault alarm
Stored up to 50,000
Automatic Monitoring
FAQs
1. What is the main function of this Automatic Electrolyte Analyzer?
It is a professional laboratory instrument designed for Automatic Electrolyte Analyzer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Automatic Electrolyte Analyzer compared to similar products?
It provides high measurement accuracy, fast analysis speed, and good repeatability. The automatic calibration and self-diagnostic functions reduce human error and ensure reliable test results for critical applications.
3. What regular maintenance is required for this Automatic Electrolyte Analyzer?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Automatic Electrolyte Analyzer?
Installation requirements include: 1) Selecting a vibration-free location to ensure measurement accuracy; 2) Providing stable power supply with voltage regulation if necessary; 3) Ensuring proper ventilation for instruments requiring gas exhaust; 4) Maintaining appropriate ambient temperature (usually 5-40℃) and humidity (≤85%) as specified in the operating manual.
5. What should I do if the Automatic Electrolyte Analyzer shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.