Introduction
Vacuum Concentrator Centrifuge efficiently removes water and organic solvents from samples, operating at speeds up to 2000 r/min. It features a micro-controller unit and a high-torque brushless motor for stable performance. centrifuge includes a transparent cover for visual monitoring of samples during the concentration process. It incorporates an aluminum alloy chamber coated with corrosion-resistant material.
Applications
Vacuum Concentrator Centrifuge is widely used in both qualitative and quantitative analyses across multiple fields such as chemical, biological, immunoscreening, food safety, residue analysis. It is suitable for liquid chromatography, ADMET/toxicology studies, polymer chemistry, DNA/RNA purification, and forensic drug testing.
Specifications
| Max Speed | 2000r/min |
| Max RCF | 500 × g |
| Rotor Capacity | 6 × 250mL |
| Adaptor Capacity | 6 × 2 × 50 ml or 6 × 5 × 20mL |
| Ambient Temperature | 0 °C to 40 °C |
| Noise | ≤ 50dB (A) |
| Temperature Control Range | Room temp to 60 °C or without Heat |
| Vacuum Degree | 0.1m bar |
| Vacuum Interface | φ10mm |
| Max Current | 7A |
| Total Power | 1.5kW |
| Power Supply | AC220V/50Hz |
| Dimension (L × W × H) | 600 × 540 × 360mm |
| Weight | 38kg |
Features
Non-Contact Drive Rotation System
Over Temperature Warning Function
LCD Touch Screen Monitor with TFT True Color
Flexible Concentration Time
Multiple rotors are available
Low noise operation
FAQ
Q1: What is the maximum rotational speed of this centrifuge?
A1: The maximum speed is 10000 RPM (varies by model), such as 15000 RPM for high-speed models and 4000 RPM for low-speed models.
Q2: Does it have a refrigeration function?
A2: No, it is a non-refrigerated centrifuge - Refrigerated models can maintain a temperature range of -20°C to 40°C, while non-refrigerated models operate at ambient temperature.
Q3: What is the maximum capacity of the rotor?
A3: The standard rotor can hold 24×10ml test tubes (e.g., 12×15ml test tubes), and optional rotors are available for different tube sizes.
Q4: How to ensure the safety of centrifugation operation?
A4: It is equipped with multiple safety protections, including imbalance detection, door lock protection, and over-temperature/over-speed protection.
Q5: What is the recommended maintenance cycle?
A5: It is recommended to clean the rotor and chamber after each use, and perform a comprehensive maintenance check every 6 months (or 500 operating hours).
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.