Gel Documentation offer reliable imaging solutions for analysing electrophoresis gels in laboratory settings. They are designed for accurate DNA, RNA, and protein visualization using high-resolution imaging and light filtering. These systems feature user-friendly interfaces, software tools, and support various fluorescent stains. Their configurations range from basic gel doc setups to fully integrated imaging analysis units with UV and blue light compatibility. Our Gel Documentation are ideal for molecular biology labs, research institutions, academic environments, and clinical diagnostics.
Gel Documentation System LBGD-T2011
Gel Documentation System features an effective pixel resolution of 2560 × 1920, providing high-definition imaging for detailed analysis. It has a high-resolution digital , ensuring accu...
Gel Documentation System LBGD-T2010
Gel Documentation System offers an effective pixel resolution of 1280 × 1024, delivering high-quality imaging with excellent clarity. It is equipped with advanced electric zoom lens pro...
Gel Documentation System LBGD-T2016
Gel Documentation System features a 9-megapixel camera that delivers highly detailed images with exceptional sensitivity. Its low-noise design minimizes background interference for clean...
Gel Imaging System LGIS-T2011
Gel Imaging System has gel viewing dimensions of 200 × 150 mm and offers a broad and clear platform for observing gel samples. It operates using visible light, eliminating the hazards o...
Gel Imaging System LGIS-T2010
Gel Imaging System with transmission dimensions of 120 × 120 mm, provides sample surface area for effective sample visualization during gel imaging. It uses a non-toxic fluorescent dye,...
Multifunctional Imager LMFI-T2013
Multifunctional Imager offers 4 fluorescent channels for detailed imaging and data analysis workflows. It ensures high-resolution imaging with advanced optics and superior light sensitiv...
Multifunctional Imager LMFI-T2012
Multifunctional Imager offers 16-bit imaging depth for enhanced data precision and clarity. Its high-resolution optics enable detection of fine sample details for comprehensive analysis....
Multifunctional Imager LMFI-T2011
Multifunctional Imager features pixel size of 4.54×4.54µm for enhanced image resolution. Equipped with high-definition cameras for capturing sharp, detailed visuals with clarity. Its a...
Multifunctional Imager LMFI-T2010
Multifunctional Imager features 9-megapixel high-resolution camera for correct imaging and analysis. Its high-sensitivity sensors detect faint signals for exceptional visualization of lo...
Gel Documentation System LBGD-T2013
Gel Documentation System offers high-resolution imaging with 6.3-megapixel clarity for correct analysis. Equipped with UV and solution for recording, evaluating, and sharing results in r...
Chemiluminescence Imaging System LCIS-T2011
Chemiluminescence Imaging System captures high-resolution images at up to 6.0 megapixel. Equipped with customizable filter set for various wavelengths of emissions. Its multi-exposure fe...
Chemiluminescence Imaging System LCIS-T2010
Chemiluminescence Imaging System features a high-resolution camera with 16-bit depth. It provides excellent sensitivity for detecting low-level chemiluminescent signals in samples. The s...
Gel Documentation System LBGD-T2015
Gel Documentation System is integrated with UV and function, reducing manual adjustments during imaging. Its adjustable zoom lens enhances focus for detailed sample visualization. Incorp...
Gel Documentation System LBGD-T2014
Gel Documentation System captures high-resolution images at up to 5.0 megapixels. It is equipped with advanced an advanced camera for accurate imaging and detailed documentation. The sys...
Gel Documentation System LBGD-T2012
Gel Documentation System offers a 16-bit cooling camera for clear detection of faint bands and low-concentration samples. The high-resolution camera ensures sharp and detailed images for...
Gel Documentation System LBGD-T2011
Gel Documentation System is a sleek body with a monitor which together provides efficient imaging and quantification capabilities. Features a built-in camera for capturing high-resolutio...
Gel Documentation System LBGD-T2010
Gel Documentation System is a close-packed vertical gel documentation system designed for nucleic acids and proteins quantification. Equipped with 16-bit high-resolution power and a high...
Chemiluminescence Imaging System LCIS-T2023
Chemiluminescence Imaging System is a new generation, an integrated device with 10.1-inch touch screen display, for used for imaging Chemiluminescence Gel with exceptionally high quantum...
Chemiluminescence Imaging System LCIS-T2022
Chemiluminescence Imaging System is a new generation, an integrated device with 10.1-inch touch screen display, for used for imaging Chemiluminescence Gel with exceptionally high quantum...
Chemiluminescence Imaging System LCIS-T2021
Chemiluminescence Imaging System is a new generation, an integrated device for used for imaging Chemiluminescence Gel with exceptionally high quantum efficiency Camera for greater sensit...
Chemiluminescence Imaging System LCIS-T2020
Chemiluminescence Imaging System is a new generation, an integrated device for used for imaging Chemiluminescence Gel with exceptionally high quantum efficiency Camera for greater sensit...
Gel Document System GDS200
Gel Document System features a 6-megapixel scientific-grade CCD camera with motorized zoom and a built-in 302 nm UV transilluminator. It supports high-resolution imaging for RNA, and prot...
Standards
Complies with the above standards, but is not limited to them.
Features
1. Precise thermal or optical control supports accurate results.
2. Program libraries and user management support shared laboratory use.
3. Multiple channels or samples support throughput.
4. Programmable protocols store cycling or imaging steps.
5. Clear display or software shows run status and data.
FAQ
What are the main applications of the Gel Documentation?
The Gel Documentation is used in molecular and cell biology for amplification, separation, imaging or sample preparation. It supports PCR, electrophoresis, nucleic-acid work and related research and diagnostic laboratories.
Which standards and regulations apply to the Gel Documentation?
The instrument is designed with reference to IEC 61010 electrical safety, applicable molecular-biology methods and relevant GB/T standards. Programs and reagents should follow validated protocols. Compliance documentation can be provided on request.
How long is the warranty period?
The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.
How easy is the Gel Documentation to use?
Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
How often should the Gel Documentation be calibrated?
To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.
Where do we get replacement parts?
The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.
Are options or configurations available?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
Is installation and commissioning included?
The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.
What maintenance and safety points matter?
Do not use contaminated samples or reagents, skip controls or block thermal or optical paths. Prevent cross-contamination and maintain calibration. Follow laboratory safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.