Introduction

Chemiluminescence Imaging System is a new generation, an integrated device with 10.1-inch touch screen display, for used for imaging Chemiluminescence Gel with exceptionally high quantum efficiency Camera for greater sensitivity and dynamic range. It offers a 12.49 × 9.99 mm Sensor Size, with 6.05 MP resolution, F0.8 motorized lens, and -30˚C cooling temperature. The 16-bit (65536 Grey Scales) camera reduces the background noise during a long exposure time. The device can detect far weaker signals, offers higher sensitivity and a wider linear range. The device configuration offered as documentation of , , Protein, and Chemiluminescence imaging system. This gel documentation is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Chemiluminescence Imaging System used in genetic engineering, biotechnology, molecular biology for obtaining high-quality images of / bands, also for protein detection, plate reading, and Chemiluminescence analysis.

Specifications

Sensor Size 12.49 × 9.99 mm
Resolution 6.05 Megapixels, 2750 × 2200
Pixel Density 16bit (65536 Grey Scales)
Pixel Size 4.54 × 4.54 µm
Lens F0.8 motorized lens
Light Source Epi-white light × 2
UV-Transilluminator (302 nm)
White- Transilluminator
Display 10.1 inch touch Screen Display
Quantum efficiency ≥ 75 %
Readout noise < 5.5e-
Dark current 0.0003 e/p/s
Dynamic range 4 order of magnitude
Standard Filter 590 nm filter
Filter Wheel 8 Sockets Filter Wheel
Max Image Area 260 × 210 mm
Cooling Temperature -30˚C
Software Image acquisition and analysis software
Dimension 560 × 480 × 780 mm + 380 × 350 × 490 mm
Gross Weight 39 kg

Features

10.1-inch touch screen display with user-friendly operation mode

≥ 75 % High Quantum efficiency of the camera

Sensor Size offered is 12.49 × 9.99 mm, with a 6.05 MP resolution

Offers convenient image navigation and browsing

Optional attachment of different fluorescent light sources and filters

Automatic pixel binning technology

Marker image capture and composition with objective bands

Small footprint - takes up minimal bench space

Configured for maximum sensitivity to ensure even the faintest band on a blot can be captured

Optional full configuration system Analysis System (, , Protein, Chemiluminescence, Fluorescence)

FAQs

1. What are the key factors to consider when selecting this gel documentation for laboratory use?

When selecting this gel documentation, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this gel documentation be calibrated to ensure accurate results?

It is recommended to calibrate this gel documentation at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this gel documentation?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this gel documentation be used with different types of samples, and are there any compatibility considerations?

Yes, this gel documentation can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the gel documentation malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.