Gel Document System features a 6-megapixel scientific-grade CCD camera with motorized zoom and a built-in 302 nm UV transilluminator. It supports high-resolution imaging for RNA, and protein gels with auto-focus precision. Equipped with JP-Gel software, enabling image enhancement, quantification, and export in JPG/TIFF formats. Integrated with a motorized filter wheel, white and blue light options, and USB/LAN connectivity, offering flexible operation and efficient data handling. Our Gel Document System is designed for electrophoresis imaging in molecular biology, research, and clinical laboratories.
Applications
Gel Document System features a 6-megapixel CCD camera with motorized zoom and built-in UV transilluminator for high-resolution imaging. It is designed for molecular biology research, academic laboratories, and clinical diagnostics requiring high-quality electrophoresis imaging.
Specifications
| CCD Chip | 1/2.5 |
| Dynamic Range | 4.5 OD, 16-Bit Grayscale |
| Minimum DNA Detection | < 20 Pg EB-Stained DsDNA |
| Sensitivity | ≥ 0.01 Ng EB-Stained DNA |
| Signal-To-Noise Ratio | ≥ 56 dB |
| Pixel Size | 5.7 µm × 4.28 µm |
| Pixel Merging Binning | 1×1, 2×2, 3×3, 4×4 |
| Lens | Motorized Zoom, 8–48 Mm, Aperture F1.2 |
| Focus And Aperture | Auto Controlled Via Software Or Panel |
| Exposure Time | 0.294 Ms To 2000 Ms |
| Excitation Light Source | 300 Nm UV Transmitted; 254 & 365 Nm UV Reflected |
| Projection Table Area | UV: 210 × 250 Mm; White Light: 210 × 300 Mm |
| Optical Filter | 590 Nm Standard; Compatible With EB, SYBR, GoldView, Etc. |
| Display & Operation | Multi-Function Control Panel With Touch Keys |
| Observation Window | UV Protection Window For Real-Time Viewing |
| Software | JP-GEL, Integrated With Analysis Tools: Band Quantification, OD, Colony Count, Excel Report Export |
| Image Formats Supported | TIFF, JPEG |
| Auto Shut-Off Timer | Light Sources Turn Off After 10 Minutes Of Inactivity |
| Supported Applications | DNA/RNA Gel Imaging, Protein Gels Coomassie, Silver Stain, GFP/ eGFP, Dot Blot, Western Blot, Autoradiography, PCR, High-Throughput Arrays |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (L × W × H) | 380 × 430 × 730 Mm |
| Net Weight | 18.4 Kg |
Features
Touch Key Control Panel.
Software and Panel Automation.
High-Resolution CCD Imaging.
Enhanced Weak Band Detection.
Real-Time Safe UV Observation.
Saves in TIFF, JPEG Formats.
Auto Light Shutdown in 10 Minutes.
Synchronized Light Source Control.
Optical Density Measurement Support.
Band Quantification and Analysis.
Colony and PCR Quantification.
Compatible with Protein and DNA Dyes.
Autoradiography and Dot Blot Ready.
Excel Report Export Function.
Integrated Capture and Analysis Software.
FAQs
1. What are Gel Documentation Systems used for?
Gel Documentation Systems are used for imaging and analyzing electrophoresis gels in molecular biology laboratories.
2. . What types of samples can be analyzed using Gel Documentation Systems?
Gel Documentation Systems are designed for accurate visualization of RNA, and protein samples.
3. How do Gel Documentation Systems ensure high-quality imaging?
Gel Documentation Systems use high-resolution imaging with optimized light filtering for clear and precise results.
4. What software features are included in Gel Documentation Systems?
Gel Documentation Systems include user-friendly software tools for image capture, analysis, and documentation.
5. What lighting options are supported by Gel Documentation Systems?
Gel Documentation Systems support UV and blue light compatibility for use with various fluorescent stains.
6. Where are Gel Documentation Systems commonly used?
Gel Documentation Systems are commonly used in molecular biology labs, research institutes, academic settings, and clinical diagnostics.
7. What are Gel Documentation Systems used for?
Gel Documentation Systems are used to capture, visualize, and analyze gel electrophoresis results with high clarity and accuracy.
8. What types of samples can be analyzed using Gel Documentation Systems?
Gel Documentation Systems support imaging of RNA, and protein samples for molecular biology applications.
9. What illumination options are available in Gel Documentation Systems?
Gel Documentation Systems support UV, white light, and blue light illumination for flexible and safe gel imaging.
10. What software and control features are included in Gel Documentation Systems?
Gel Documentation Systems include intuitive software, motorized components, and filter options for fluorescent dye analysis.
11. How do Gel Documentation Systems support advanced analysis?
Gel Documentation Systems offer precise imaging configurations that enable both routine documentation and advanced analytical workflows.
12. Where are Gel Documentation Systems commonly used?
Gel Documentation Systems are commonly used in academic laboratories, research centers, pharmaceutical studies, and clinical diagnostics.