Horizontal at ≤65 dB(A), ensuring quiet performance for lab use. It ensures a clean workstation, ideal for contamination-sensitive environments. The advanced filtration system delivers sterile, particle-free horizontal airflow. This protects samples from airborne contaminants during critical procedures. Our Horizontal sterile applications.
This clean benches is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Horizontal Laminar Flow Clean Bench ensures contamination control during critical processes such as sample handling, inspection, and packaging in laboratories and cleanroom environments for reliable and sterile results.
Specifications
| Airflow Velocity | 0.3 to 0.5 m/s |
| Filter | > 99.999% efficiency at 0.3 µm |
| Cleanliness Grade | Class 5, Class 100 (Fed 209E) |
| Sound Emission | ≤ 65 dB(A) |
| ≤ 4 µm | |
| Fluorescent Light | 16 W |
| UV Light | 21 W |
| Power Consumption | ≤ 0.5 Kw |
| Power Supply | AC 220 ± 10% / 50 HZ |
| External Dimension | 1000 × 750 × 1470 mm |
| Internal Dimension | 920 × 500 × 600 mm |
| Net Weight | 50 Kg |
Features
Low-Turbulence Airflow
Transparent Side Panels
Integrated Monitoring Display
Bright Illumination Lamp
Compact and Ergonomic Design
FAQs
1. What is the main function of the Horizontal Laminar Flow Clean Bench ?
The primary function of the Horizontal Laminar Flow Clean Bench is to provide a sterile and contamination-free workspace by directing filtered air in a horizontal laminar flow across the work surface. This continuous airflow removes airborne contaminants, protecting sensitive samples and processes. It is ideal for tasks such as sample preparation, inspection, and packaging where contamination control is critical. The filter ensures removal of particles as small as 0.3 microns with 99.99% efficiency. Additionally, the built-in UV light can sterilize the workspace when the bench is not in use. This combination of features supports maintaining a clean environment suitable for laboratories and cleanrooms.
2. How does the filter in Horizontal Laminar Flow Clean Bench improve lab safety and cleanliness?
The filter in the Horizontal Laminar Flow Clean Bench plays a crucial role in removing 99.99% of airborne particles larger than 0.3 microns, including dust, microbes, and other contaminants. This high-efficiency filtration ensures that the air blowing over the work surface is free from harmful particles, thereby protecting samples and experimental processes from contamination. It enhances lab safety by minimizing the risk of exposure to potentially hazardous biological or chemical materials. The filter is easy to maintain and replace, ensuring long-term performance. By providing a controlled clean airflow, the filter helps labs meet stringent cleanliness standards required for sensitive applications.
3. Can the Horizontal Laminar Flow Clean Bench be customized for different laboratory needs?
Yes, the Horizontal Laminar Flow Clean Bench can be customized to meet specific laboratory requirements. Options may include varying internal sizes, additional electrical outlets, different types of illumination such as lamps, or enhanced filtration systems. Some models allow integration with monitoring systems for airflow and filter status to suit advanced lab environments. Customization ensures the clean bench can accommodate diverse applications such as pharmaceutical preparation, electronics assembly, or microbiological research. Users should consult with suppliers or manufacturers to select the best configuration based on their operational needs.
4. How does the integrated screen enhance user experience in the Horizontal Laminar Flow Clean Bench ?
The integrated screen in the Horizontal Laminar Flow Clean Bench provides real-time monitoring of critical parameters such as airflow velocity, filter status, and operating time. This feature allows users to quickly verify that the clean bench is functioning within safe and optimal limits. It also simplifies maintenance by alerting users when filter replacement or UV lamp servicing is needed. The clear display enhances user confidence by providing easy access to performance data without disrupting work. Overall, the screen helps ensure safety, reliability, and efficient operation in laboratory workflows.
5. How does the UV light function in the Horizontal Laminar Flow Clean Bench , and when should it be used?
The UV light in the Horizontal Laminar Flow Clean Bench is designed for surface sterilization to eliminate bacteria, viruses, and fungi on the internal surfaces of the clean bench. It should be operated only when the bench is not in use and the front sash is closed, to prevent exposure to harmful UV radiation. Running the UV light before and after work sessions helps maintain a sterile environment by killing residual microorganisms. This sterilization step is crucial in microbiology, pharmaceutical, and medical laboratories where contamination must be minimized. Users should follow manufacturer guidelines to avoid overuse and ensure the UV lamp’s effectiveness.