Introduction

Plant Growth Chamber features controlled temperature environment from 0℃ to 55℃. circulation fan with optimized air duct ensures temperature stability within ±1℃ range. Polished stainless-steel chamber with adjustable shelves allows convenient cleaning. Dual refrigeration systems alternate automatically to ensure failure-free long-term operation. Ideal for horticulture, botanical studies, phytopathology research and seed germination studies.

This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Plant Growth Chamber is ideal for horticulture, botanical studies, phytopathology research, seed germination studies and plant development research.

Specifications

Capacity 475L
Temperature Range With light:10 to 55℃
Temperature Stability Less than or equal to ±1℃
Temperature Uniformity Less than or equal to ±1℃
Operating Temperature +5 to 35℃
Display Resolution 0.1℃
Light Intensity Adjustment 0 to 30000
Shelves 3/22
Power Consumption 2900W
Power Supply AC220V, 50HZ
Chamber Size 700 × 550 × 1250
Exterior Size 880 × 870 × 1995mm
Weight 115Kg

Features

Over heat protection

Flexible shelf positions

Compressor safety guard

Audio-visual alarm system

Features mechanical thermostat

FAQs

1. What are the key factors to consider when selecting this test equipment for laboratory use?

When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this test equipment be calibrated to ensure accurate results?

It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this test equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the test equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

1. What temperature and lighting capabilities does the Plant Growth Chamber provide?

The Plant Growth Chamber delivers a programmable temperature range of 0°C to 55°C in dark mode, shifting to 10°C to 55°C when lights are active. circulation fan and an optimized air duct system keep stability and uniformity within ±1°C. Light intensity is adjustable from 0 to 30,000lux across six levels, allowing precise simulation of dawn, shade, or full sunlight. A 0.1°C display resolution supports fine set point adjustment for sensitive trials. Dual refrigeration circuits ensure rapid cooling and reliable diurnal transitions. Together, these functions replicate natural day night cycles for controlled plant development experiments.

2. How does the design of the Plant Growth Chamber support flexible, high throughput research?

Plant Growth Chamber features a spacious 475L polished stainless steel chamber resists corrosion and wipes clean easily after nutrient spills. Three perforated shelves ship as standard, while twenty two height positions accommodate tall plants or stacked flats. Adjustable grids and forced air circulation prevent hot or cold spots across shelf tiers. An internal power outlet lets you run shakers, data loggers, or CO2 sensors without compromising the door seal. The large 880×870×1995mm footprint balances capacity with lab floor efficiency. These features make the unit suitable for parallel experiments or long term grow outs.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.