Introduction

IR Carbon and Sulfur Analyzer features four independent infrared detection pools for accurate carbon and sulfur analysis. It measures carbon from 0.001 to 50% and sulfur from 0.00001 to 5%, ensuring broad testing applications. The device provides precise readings with a sensitivity of 0.01 ppm, making it suitable for trace-level analysis. Equipped with a high-quality ceramic electron tube, it enhances durability and reliability. Ideal for laboratories requiring accurate elemental analysis of metals, minerals, and other materials.

This ir carbon sulphur analyzer is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our IR Carbon and Sulphur Analyzer accurately determines carbon and sulfur content. It is ideal for metallurgy, steel manufacturing, foundries, and quality control labs.

Specifications

Carbon Measurement Range C1: 0.001 to 50% (expandable to 100%)
C2:0.00001% to 0.5%
Sulfur Measurement Range S1: 0.00001 to 5% (scalable)
Sensitivity 0.01 ppm
Analysis Time 30 to 50 s
Accuracy Standard () - Carbon Less than or equal to 0.4%
Accuracy Standard () - Sulfur less than or equal to1.0%
Detector 4 sets (high/low carbon, low sulfur, CO)
Measurement Principle High-frequency combustion infrared absorption
Analysis Gas Pure oxygen 99.5%
Power Gas Nitrogen or anhydrous compressed air
Electron Tube Ceramics
Light Source Nichrome wire
Modulating Motor 30,000 hours without failure
Absorption Pool Coating Material Gold plated
Flow Meter Digital quality
Filter Metal micropores
Way of Communication Serial port
Power 2.5 kW
Dimensions 575×455×725 mm
Weight 80 kg

Features

User-Friendly Digital Interface

Metal Micropore Filtration System

Automatic Dust Removal Mechanism

Advanced Peak Width Compensation

Temperature and Flow Adjustments

Dual Operating System

FAQs

1. What are the key factors to consider when selecting this ir carbon sulphur analyzer for laboratory use?

When selecting this ir carbon sulphur analyzer, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this ir carbon sulphur analyzer be calibrated to ensure accurate results?

It is recommended to calibrate this ir carbon sulphur analyzer at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this ir carbon sulphur analyzer?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this ir carbon sulphur analyzer be used with different types of samples, and are there any compatibility considerations?

Yes, this ir carbon sulphur analyzer can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the ir carbon sulphur analyzer malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.