Introduction
Mini Centrifuge operates at maximum speed ranges from 2,000 rpm to 10,000 rpm with precise 1,000 rpm incremental adjustments. Its quick spin function enables rapid sample separation for time-sensitive laboratory applications. Equipped with operational status for easy monitoring during centrifugation. Feature automatic imbalance detection that prevents operational failures and enhances instrument safety. Offers efficient air circulation minimizing heat buildup, protecting temperature-sensitive samples.
It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.Applications
Our Mini Centrifuge ensures precise and efficient separation of biological and chemical samples in research, diagnostics, and laboratory workflows, offering high-speed performance, user-friendly operation, and enhanced safety features.
Specifications
| Max. Speed | 2000 rpm to 10000 rpm, increment: 1000rpm |
| Max. | 6708×g to 1.5/2ml; 6596 to 7490×g to 8 strips |
| Rotor Capacity | 0.2mL × 44 tubes 0.5/1.5/2mL × 12 + 0.2ml 8-strips× 4 |
| Noise Level | ≤58dB |
| Run Time | 10sec to 20min |
| Display | |
| Acceleration and Deceleration | Increase-1 and Decrease-2 |
| Driving Motor | DC motor |
| Power Consumption | 40W |
| Power Supply | V/50Hz/60Hz |
| Dimension (D×W×H) | 210mm×180mm×130 mm |
| Weight | 1.5 kg |
Features
Maximum speed with high
Switch speed and time easily
Smooth DC motor operation
Quiet and stable performance
Safe and durable rotor
Clamp locking rotor design
Easy-to-use operating system
Wide voltage stability technology
High speed accuracy ensured
Compatible with multiple tubes
Supports strip tubes
Soft braking and stop modes
Adjustable screen button controls
FAQs
1. What is the maximum sample volume that can be processed in the centrifuge?
The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.
2. How to balance the centrifuge before operation?
Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.
3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?
RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.
4. How to maintain the centrifuge to ensure long service life?
Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.
5. What safety precautions should be taken when using the centrifuge?
Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.