Introduction
Type I and Type II RO Water Purification System has a production capacity of 10 316L stainless steel filter for fine impurity removal. Its long-acting device removes chlorine and heavy metals. The system is equipped with advanced a portable test pen to measure and conductivity with accuracy. Its backlight monitoring of water quality. Our system provides reliable purification for a wide range of laboratory tasks.
This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Type I and Type II RO Water Purification System is commonly used in laboratories, hospitals, and research institutions for applications requiring high-purity water, such as in medical testing and chemical analysis.
Specifications
| Capacity | 10 L per hour |
| Production Speed | 1.5 to 2 L (with pressure barrel) |
| Water Requirements | Urban tap water, Inlet pressure: 0.15 to 0.5 MPa, Temperature: 5℃ to 40℃ |
| RO Water Ion Rejection Rate | 97% to 99% (using a new RO membrane) |
| RO Water Organic Matter Rejection Rate | > 99% when MW > 200 Dalton |
| RO Water Particle & Bacterial Rejection | >99% |
| RO Water Application | Clean glassware |
| Type II Water Resistivity (25℃) | 10 to 16 MΩ·cm |
| Type II Water Conductivity | < 0.1 µS/cm |
| Type II Water | < 30 ppb |
| Type II Water Application | Biochemical analyzer, cleaning, microbial culture media |
| Type I Water Resistivity (25℃) | 18.25 MΩ·cm |
| Type I Water Heavy Metal Ion | < 0.01 ppb |
| Type I Water | < 3 ppb |
| Type I Water Bacteria | < 1 cfu/mL (with terminal filter) |
| Type I Water Particulate Matter | < 0.1 microns |
| Type I Water Pyrogen (Endotoxin) | < 0.001 EU/ml |
| Type I Water RNase | < 1 pg/ml |
| Type I Type I Water DNase | <1 ng/ml |
| Type I Water Application | Molecular biology, gene research, drug development |
| Power | 48 to 72W |
| Power Supply | 100 to 240V, 50/60Hz |
| Dimension | 450 × 470 × 550 mm |
| Packaging Dimension | 550 × 630 × 680 mm |
| Net Weight | 35 kg |
| Gross Weight | 42 kg |
Features
Manual drain valve with automatic cleaning
Transparent pressure tank with anti-bacterial pouch
engineering plastic case with powder coating
Menu-type operation with adjustable parameters
Water quality exceeding alarm
Dual-wavelength UV lamps for sterilization
FAQs
1. What are the key factors to consider when selecting this water purification system for laboratory use?
When selecting this water purification system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this water purification system be calibrated to ensure accurate results?
It is recommended to calibrate this water purification system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this water purification system?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this water purification system be used with different types of samples, and are there any compatibility considerations?
Yes, this water purification system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the water purification system malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.