Introduction

UV Transilluminator provides reflection wavelengths with options at 254 nm and 365 nm and a 302 nm transmission wavelength. Its powerful 12-piece 6W UV lamps ensure strong, consistent illumination. It offers UV light filtration that filters out unwanted light, ensuring stable UV for fluorescence analysis. Our transilluminator delivers 99% UV filtration with observation windows enabling real-time, safe sample monitoring.

This transilluminator is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

UV Transilluminator utilizes various UV wavelengths to observe and photograph / gel samples, detect proteins, and nucleic acids, and perform analyses such as nucleic acid electrophoresis, product detection, fingerprint mapping, and thin-layer chromatography.

Specifications

Reflection Wavelength 254, 365nm
UV Lamp Power 6W
UV Lamp Capacity 12pcs
Transmission Filter Size 200×80mm
Drive Filter Size 200×200mm
White Light Plate Size 210×260mm
Transmission Wavelength 302nm
Visible Light 60W
Operation Ports Left and Right sides
Observation Port Anti-ultraviolet observation port
UV Intensity 20 cm UV intensity at 20 µW/cm²
Power Supply AC220V,50/60HZ
Dimension 375 × 280 × 380 mm
Packaging Dimension 480 × 395 ×535 mm
Net Weight 4.88 Kg
Gross Weight 7 Kg

Features

Lightweight and compact

Easy to handle and operate

Ship-type switch for wavelength control

Nano-Grade UV Intensity

FAQs

1. What are the key factors to consider when selecting this transilluminator for laboratory use?

When selecting this transilluminator, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this transilluminator be calibrated to ensure accurate results?

It is recommended to calibrate this transilluminator at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this transilluminator?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this transilluminator be used with different types of samples, and are there any compatibility considerations?

Yes, this transilluminator can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the transilluminator malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.