Introduction

Nano Spectrophotometer comes with a wavelength range of 180 to 910 nm, designed for a wide range of analytical applications. It delivers fast detection times between 2 and 6 seconds. With precise path length control, it provides highly accurate and reliable results. The model also includes heating capabilities of up to 37°C, making it ideal for kinetic assays. It enables continuous monitoring of enzyme activity, chemical reactions, microbial growth, and other dynamic biological processes.

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Nano Spectrophotometer is perfect for various workflows in molecular biology, environmental testing, and food safety analysis, making it an invaluable tool in any laboratory setting.

Specifications

Wavelength Range 180 to 910 nm
Sample Volume 0.5 to 2.0 µL (recommended 2.0 µL)
Wavelength Accuracy ±1 nm
Path Length 0.03 mm, 0.05 mm, 0.1 mm, 0.2 mm, 1.0 mm
Measurement Time Less than 6 seconds
Stirring Speed 100 to 900 rpm
Heating Temperature Up to 37°C
Light Source Xenon flash lamp (109 flashes)
Detector 2048-element linear array
Spectral Resolution Up to 1.5 nm
Absorbance Precision 0.002 Abs
Absorbance Range 0.02 to 750 A (equivalent to 10 mm)
Concenteration Accuracy ±1% (7.332 Abs at 260 nm)
OD600 Absorbance Range 0 to 4.000 Abs
Concentration Range 2 to 37500 ng/µL (dsDNA)
Absorbance Stability [0,3] ≤ 0.5%, [3,4] ≤ 1.5%
Absorbance Repeatability [0,3] ≤ 0.5%, [3,4] ≤ 1.5%
Data Export
Input Power 48 W
Power Supply DC 12V, 4A
Dimensions 300 × 232 × 196 mm
Net Weight 3.6 kg

Features

7-inch touchscreen with Android UI

Weighs slightly less at 3.6 kg

Wider absorbance range

Stirring speed control from 100 to 900 rpm

Built-in printer and export capability

Supports direct or cuvette measurements

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.