Introduction
Automatic Kinematic Viscometer measures fluid viscosity with temperature control (20-100°C (degrees Celsius), ±0.1°C (degrees Celsius)). Automatically calculates kinematic viscosity based on flow time measurement. Features multiple sample positions (up to 8) for high-throughput testing. Equipped with touchscreen interface and data storage (5000+ records). Complies with ASTM, ISO, and DIN standards. Suitable for petroleum, polymer, and lubricant analysis.
Automatic Kinematic Viscometer T-S2KV-S2101
Automatic Kinematic Viscometer T-S2KV-S2100
Standards
ISO 3219:1993-Plastics-Determination of viscosity using a rotational viscometer with defined shear rate
ISO 23581:2024-Petroleum products-Determination of kinematic viscosity by Stabinger type viscometer
ASTM D445-24-Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids
ISO 3104:2023-Petroleum products-Transparent and opaque liquids-Determination of kinematic viscosity
GB/T 265-Petroleum products-Determination of kinematic viscosity and calculation of dynamic viscosity
ASTM D2196-20-Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Complies with the above standards, but is not limited to them.
Features
1. Automatic calculations and pass limits speed quality checks.
2. Rotational or capillary method gives reliable viscosity values.
3. Temperature jacket or probe supports controlled measurements.
4. Interchangeable spindles or tubes cover wide ranges.
5. Clear display shows viscosity, speed and temperature.
FAQ
What are the main applications of the Automatic Kinematic Viscometer?
The Automatic Kinematic Viscometer is used to measure the viscosity or flow behaviour of fluids. It supports formulation, batch consistency and quality control in paints, oils, food, pharmaceuticals, chemicals and cosmetics.
What standards does the Automatic Kinematic Viscometer comply with?
The instrument is designed with reference to applicable ISO, ASTM and GB/T standards for viscosity measurement and IEC 61010 electrical safety. Procedures should follow the relevant standard method. Compliance documentation can be provided on request.
What warranty comes with the Automatic Kinematic Viscometer?
The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.
Will staff need special training?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Is calibration included?
Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.
Where do we get replacement parts?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Can the Automatic Kinematic Viscometer be customised?
Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.
How is the Automatic Kinematic Viscometer commissioned?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What maintenance and safety points matter?
Do not use samples outside the viscosity range, introduce bubbles or use damaged spindles. Control temperature, since viscosity is temperature dependent. Follow the operating instructions.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.