Introduction

Pharmacy Refrigerator is a digital microprocessor controlled temperature refrigerator with holding capacity of 656 liters and adjustable design storage shelves. Features Inbuilt full automatic defrost system with -Free refrigerant. It has standard electrical heater with double glass observation door and Noiseless, user friendly operation mode. Auto audio-visual signal alarm protection and it temperature ranges from 2 to 8°C/15°C with the display.

This refrigerators is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

The pharmacy refrigerator is suitable for installation in drug stores, pharmacy companies, hospitals, epidemic prevention centre’s to store medicines, testing kits, reagents, vaccines etc.

Specifications

Cabinet Type Upright
Gross Capacity 656 L
Climate Class 10 to 32°C
Cooling Type Forced Air Cooling
Defrost Mode Automatic
Refrigerant -Free
Door Double Glass Door
Noise 42 dB
Temperature Range 2 to 8℃/15℃
Uniformity ± 3°C
Temperature Control Microprocessor
Display
Internal Dimension 1100 × 454 × 1325 mm
External Dimension 1220 × 642 × 1885 mm
Packing Dimension 1290 × 695 × 1940 mm
Power Voltage 220 to 240 / 50 to 60 V/Hz
Power Supply 443 W
Net Weight 158 kg
Gross Weight 188 kg

Features

Accurate temperature control to make inner temperature maintain 2 to 8 ℃ and increment at 0.1℃

High-tech integrated sensors to display and control temperature

Auto-defrost to remove moisture on cooling surface

Removable outdoor double seal design for better temperature maintain and energy saving

Microprocessor controlled forced-air cooling system

Digital temperature displays with 0.1℃ resolution

Equipped with double layer door

-Free refrigerant and Shelves adjustable design

Epoxy coated exterior anti-bacteria and easy cleaning

Caster with break design for easy moving and lock

Interior light for easy observation

Electrical heater to decrease condensation on door in high humidity environment

Equipped by Five alarm conditions High/Low Temperature; Power Failure; Sensor Error; Door Ajar, Low Voltage in Backup Battery

FAQs

1. What are the key factors to consider when selecting this refrigerators for laboratory use?

When selecting this refrigerators, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this refrigerators be calibrated to ensure accurate results?

It is recommended to calibrate this refrigerators at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this refrigerators?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this refrigerators be used with different types of samples, and are there any compatibility considerations?

Yes, this refrigerators can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the refrigerators malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.