Introduction

Refrigerated Centrifuge features a maximum speed of 16,000 rpm, suitable for a wide range of applications. Its advanced cooling system maintains a temperature range from -20°C to -40°C, ensuring sample stability. This centrifuge offers a programmable time range, acceleration and deceleration profiles, and convenient / conversion. It enhances user safety with an automatic electric lid lock, imbalance sensor, and protections against over-temperature and speed. In addition, this centrifuge ensures safe and user-friendly operation for demanding laboratory environments.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Our Refrigerated Centrifuge is widely used in research and clinical laboratories for applications that require efficient separation of biological samples under precise temperature control. 

Specifications

Maximum speed 16000 rpm
Maximum 27170 × g
Maximum capacity 4 × 250 ml
Temperature range -20°C to -40°C
Temperature accuracy ± 1°C
Speed accuracy ± 20 rpm
Time range 0 to 99 h 59 min
Cooling cycle Double
Noise ≤ 55 dB
/ convert Yes
Acceleration/Deceleration 10 kinds
Memory 10 programs
Controller Microprocessor
Display
Sensor Imbalance sensor
Motor Brushless frequency motor
Lid lock Automatic electric lid lock
Protection Over temperature and over speed protection
Power supply AC 220/110 V, 50/60 Hz
Package dimension (W × D × H) 620 × 600 × 360 mm
Gross weight 105 kg

Features

Compact Tabletop Design

Microprocessor Control

Eco-Friendly Compressors

Brushless Frequency Motor

Smooth Acceleration/Deceleration

Double Cycle Cooling

Display

Auto Electric Lid Lock

Multiple Program Memory

Over-Temp Protection

Over-Speed Protection

Imbalance Sensor

/ Conversion

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.