Introduction
An analytical ferrograph is an instrument used for the analysis of the wear particles in the lubricating oils, by the separation and the examination of the ferromagnetic and the non-ferromagnetic particles, and it is used in the oil analysis, the condition monitoring, and the predictive maintenance. The analytical ferrograph separates the wear particles from the oil sample by the magnetic field, depositing them on a glass slide or a substrate in the order of the size, and the deposited particles are examined under the microscope, and the concentration, the size, the morphology, and the composition of the particles are analyzed, which indicate the wear modes and the sources of the wear in the machinery; the analytical ferrograph consists of a sample preparation and a delivery system, a magnetic separation system, a deposition system, and a microscope with the illumination, and it provides the ferrogram for the analysis; the analytical ferrograph is used for the analysis of the wear particles in the lubricating oils, for the monitoring of the condition of the engines, the gearboxes, the bearings, and the other machinery, for the detection of the abnormal wear, for the diagnosis of the wear modes, for the predictive maintenance, and for many other applications, and it is an essential instrument for the wear particle analysis. Analytical ferrographs are used in the industrial maintenance, in the laboratories, in the power plants, in the transportation, and for many other applications. With their wear particle analysis, analytical ferrographs are essential for the condition monitoring.
Analytical Ferrograph LAFG-T2010
Analytical Ferrograph is a high-efficiency equipment to test and analyze lubricating oil for the evolution of machine lubricating systems. It is also used for wear status analysis of mac...
Analytical Ferrograph LAFG-T2011
Analytical Ferrograph used to monitor and analyze the reliability and predict the potential failure in lubrication parts. It uses a ferromagnetic field to set the standard for equipment ...
Analytical Ferrograph LAFG-T2010
Analytical Ferrograph is used for accurate and reliable prediction of the wear and potential failure of machine lubricants. It has a power supply of 220 V, which can generate a magnetic...
Standards
Complies with the above standards, but is not limited to them.
Features
1. Analytical ferrograph for wear particle analysis.
2. Ferrograph preparing and reading ferrograms.
3. For used-oil wear diagnosis.
4. Includes ferrograph, magnets, reader option and controls.
5. Deposits and analyzes wear particles.
FAQ
Q1: What scenarios is this ferrograph used for?
A: It deposits magnetic wear particles from used oil onto a ferrogram and supports optical analysis for wear diagnosis.
Q2: What standards does it comply with?
A: It follows ferrography and oil-analysis practices and GB/T standards, with flow and magnets verified. We confirm the stated performance during final inspection and can supply a certificate of conformity together with supporting documents for audit purposes.
Q3: What is the warranty?
A: It carries a 12 to 24 month warranty covering the unit. Damage from misuse is excluded.
Q4: Is it hard to operate?
A: It requires trained staff for sample prep and particle interpretation. We provide a manual and training.
Q5: What is the lead time?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is calibration required?
A: Performance should be verified periodically using calibrated reference standards, with results logged in the equipment record. Most users perform this check every 6 to 12 months or according to their internal quality schedule. We provide the procedure, reference materials and formal calibration service if required.
Q7: Are consumables universal?
A: These are disposable consumables and should be replaced after use to avoid cross-contamination. They are standard laboratory items available directly from us or from general laboratory suppliers, which keeps running costs low. We recommend keeping a small stock, and bulk pricing is available for regular orders.
Q8: Can it be customized?
A: Yes, several configurations are available. Options include direct-reading features and combined analytical systems. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.
Q9: Is installation included?
A: No installation is required for this unit. It is ready to run after a simple power connection and the leveling steps shown in the manual. We supply a detailed operation guide and online setup videos, and on-site commissioning can be arranged separately if your facility requires it.
Q10: What samples are compatible?
A: It handles used lubricating oils with ferrous particles within range. It is not for non-oil samples, non-ferrous-only wear without other methods, or oils beyond preparation.