Introduction

Benchtop Density Meter is a compact, portable digital density meter designed as per D792, D297, 2781, 1183, standard configurations. Features 0.005 g to 300 g of weight measuring range and 0.001 to 99.999 g/cm3 of density measuring range with 5 seconds of response time. Designed with built-in battery, large color display and printer and computer interface, this density meter has corrosion-resistant large error integrally molded sink design. With density measurement station in one injection molding, configuration windshield and buzzer system, supports temperature/solution compensation setting function and lower and upper limit function, offers direct readings for density and volume of solid, particles and floating body in any shape.

This density meter is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Density Meter is used for density determination of rubber, plastic, wire and cable, electrical appliances, sports equipment, tires, glass products, hard alloy, powder metallurgy, magnetic materials, seals, ceramics, sponge, materials, foam materials, alloys, friction materials, new materials, battery materials etc.

Specifications

Weight measuring range 0.005 to 300 g
Accuracy 0.001g/cm3
Density measuring range 0.001 to 99.999 g/cm3
Measuring object Solid, granular, film, floating body, Liquid (optional)
Response time 5 seconds
Temperature compensation Can be set from 0 to 100 ℃
Solution compensation Can be set to 19.99
Display Digital
Battery Built-in battery
Dimension (L×W×H) 430×200×370 mm
Weight 5.5 kg

Features

A compact, portable digital density meter designed as per D792, D297, 2781, 1183, standard configurations

0.005 g to 300 g of weight measuring range and 0.001 to 99.999 g/cm3 of density measuring range with 5 seconds of response time

Built-in battery, large color display and printer and computer interface for convenient operation

Corrosion-resistant large error integrally molded sink design, to test relatively large massive objects

Density measurement station in one injection molding, easy and installation with long-life

Configuration windshield, for convenient field testing and buzzer system

Temperature/solution compensation setting function with lower and upper limit function

Offers direct readings for density and volume of solid, particles and floating body in any shape

Highly-efficient, stable and reliable with easy operation and outdoor portability

FAQs

1. What are the key factors to consider when selecting this density meter for laboratory use?

When selecting this density meter, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this density meter be calibrated to ensure accurate results?

It is recommended to calibrate this density meter at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this density meter?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this density meter be used with different types of samples, and are there any compatibility considerations?

Yes, this density meter can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the density meter malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.