Introduction
Automatic Particle Counter features wide detection range, capable of identifying particles from 0.8μm to 500μm. The particle counter offers 32-channel configuration allowing custom particle size intervals as fine as 0.01μm. It generates comprehensive pollution monitoring and analysis reports quickly and accurately, supporting informed decision-making and compliance documentation. This counter is equipped with advanced a high-resolution, large-size sensor, it provides superior accuracy for consistent and trustworthy results. Our is an essential tool for industries where fluid purity is critical.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Automatic Particle Counter safeguards vital equipment by continuously monitoring fluid cleanliness in systems ranging from aircraft hydraulics to power plant turbines. Its application is crucial for predictive maintenance, enabling users to detect wear debris early and prevent costly downtime. It ensures operational integrity and adherence to all major international cleanliness standards.
Specifications
| Measurement Principle | Light Blocking Method |
| Light Source | Semiconductor Laser |
| Detection Range | 0.8μm to 500μm |
| Particle Size Channels | 32 channels, customizable in 0.01μm intervals |
| Sensitivity | 1μm ( 4402) or 4μm ( 11171 / GB/T 18854) |
| Particle Size Range | 1 to 100μm ( 4402), or 4 to 70μm ( 11171 / GB/T 18854) |
| Sample Volume | 0.3 mL to 300 mL |
| Sampling Volume Error | Better than ±10% |
| Detection Speed | 5 to 60 mL/min (Default: 15 mL/min) |
| Cleaning Speed | 5 to 60 mL/min (Default: 15 mL/min) |
| Resolution | Better than 10% |
| Coincidence Error Limit | 12,000 to 40,000 particles/mL |
| Count Repeatability () | < 2% |
| Count Accuracy | ± 0.5 particle count ratio (per 4406) |
| Count Relative Error | ±2% |
| Max Sample Pressure | 0.8 MPa (Max Positive Pressure) |
| Max Sample Vacuum | -0.08 MPa |
| Sample Viscosity Range | ≤ 600 cSt |
| Sample Temperature Range | 0°C to 80°C |
| Operating Temperature | -20°C to 80°C |
| Storage Temperature | -30°C to 80°C |
| Calibration Options | , , Latex Ball, |
| Data Output & Storage | Built-in printer, Software database, flash drive |
| Control System | Industrial Computer with Windows OS |
| Power Consumption | 180W |
| Power Supply | 200-240VAC ±10%, 50Hz |
| Dimensions | 365mm x 360mm x 600mm |
| Weight | 15 kg |
Features
High Sensitivity particle detection
High-Performance Light Source
High Coincidence Error Limit
Integrated Operating System
Low Repeatability Error
Minimal Counting Error
High-Resolution Sensor
Fully Compliant Design
Robust Sample Handling
Multiple Storage Options
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.