Introduction
Handheld Airborne Particle Counter offers a measurement range of 0 to 1000µg/m³ for accurate monitoring of airborne particulate matter. It supports zero calibration with a one-button full-channel auto-zero function, eliminating zero offset for accurate measurements. Displays an alarm status prompt on the screen for quick notification. Our Handheld Airborne Particle Counter is used to monitor airborne particles in various environments.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Handheld Airborne Particle Counter is a portable device designed to detect and measure airborne particulate matter with high accuracy. It is widely applied in cleanrooms, pharmaceuticals, environmental monitoring, electronics, and industrial safety control.
Specifications
| Measure Range | 0 to 1000µg/m³ |
| Flow Rate | 0 to 500 mL/min |
| Channel Thresholds | 0.3, 0.5, 1.0, 2.5, 5.0, 10 µm |
| Resolution | 1µg/m³ |
| Accuracy | Less than or equal to ±1% F.S. |
| Detection Principle | Laser principle |
| Working Environmental Pressure | 96 to 106KPa |
| Display | 480×320 High-resolution colour 3.5-inch |
| Storage Temperature | -40 to 50°C |
| Operating Temperature | -20 to 50 °C |
| Charging Time | 2hours |
| Operating Humidity | 0 to 95% RH |
| Operating Time | Pump opened: 10 hours, and pump closed: 24 hours. |
| Explosion-proof | Ex ic T3 Gc |
| Dimensions (W×H×D) | 75 × 170 × 41 mm |
| Net Weight | 400 g |
| Gross Weight | 1.5 Kg |
Features
Fast battery charging
Laser scattering principle
High detection resolution
Compact portable size
Broad temperature tolerance
FAQs
1. What environments is the Handheld Airborne Particle Counter ideal for?
The Handheld Airborne Particle Counter is designed for versatile use across multiple industries. It can be applied in cleanrooms to ensure compliance with standards. In pharmaceutical manufacturing, it is used for monitoring sterile filling and production lines. The electronics industries use it to prevent microscopic dust from damaging components. Environmental agencies deploy it for outdoor air quality assessments. engineers rely on it for filtration and duct performance checks. The food and medical device industries apply it to maintain hygiene and safety standards. Its portability makes it suitable for both on-site inspections and laboratory validation.
2. How does the Handheld Airborne Particle Counter help ensure cleanroom standards?
Handheld Airborne Particle Counter measures particle sizes as small as 0.3 µm. It provides accurate particle counts that help classify cleanrooms. Operators can quickly detect airborne contamination sources inside controlled environments. Its high accuracy ensures critical processes remain compliant with regulatory guidelines. The device allows routine checks during cleanroom operation and maintenance. By monitoring thresholds, users can prevent product contamination and downtime. The makes results easy to read and interpret on the spot. This helps facilities maintain consistent cleanroom performance at all times.
3. Can the Handheld Airborne Particle Counter be used outdoors?
Yes, the Handheld Airborne Particle Counter is suitable for both indoor and outdoor use. It can monitor urban air quality for environmental health studies. Researchers can measure particulate matter such as PM2.5 and PM10. It is valuable for industrial site monitoring and dust emission studies. Government agencies may use it for compliance with environmental standards. The rugged design allows it to withstand varied outdoor conditions. It provides real-time data collection for fast decision-making. This makes it a reliable tool for environmental field surveys.
4. Why use the Handheld Airborne Particle Counter for cleanroom troubleshooting?
Handheld Airborne Particle Counter is lightweight and portable for quick inspections. It detects abnormal particle levels that indicate contamination sources. Technicians can track particle increases during equipment operation. It helps identify leaks in filters or faulty air circulation. Fast response time enables immediate corrective action. The device can be used during cleanroom certification or after incidents. Alarm prompts allow users to act on deviations quickly. This reduces downtime and maintains strict cleanroom compliance.
5. How does the Handheld Airborne Particle Counter support pharmaceutical monitoring?
In pharmaceutical applications, the Handheld Airborne Particle Counter plays a crucial role in maintaining contamination control. It ensures that airborne particles remain within regulatory limits and is commonly used in isolators, filling lines, and clean zones. Its high accuracy protects sensitive products from contamination and supports routine compliance audits. Reliable data recording provides proper documentation for regulatory inspections. By preventing costly batch rejections caused by airborne particles, it strengthens product safety. Its portability allows flexible use across multiple production areas. The device contributes to consistent environmental monitoring in critical zones. Overall, it is indispensable in pharmaceutical quality assurance processes.
6. Is the Handheld Airborne Particle Counter suitable for electronics manufacturing environments?
Yes, the Handheld Airborne Particle Counter plays a vital role in electronics. It monitors microscopic particles that could damage circuits and wafers. Semiconductor fabs rely on it to prevent defects during chip manufacturing. Display panel production benefits from particle-free assembly lines. It enables engineers to track cleanroom efficiency in electronics plants. Fast detection helps prevent yield loss in sensitive processes. The lightweight design makes inspections across multiple sites easier. Thus, it safeguards product reliability in high-tech industries.
7. How does a handheld airborne particle counter work?
By employing different methods such as light scattering, light obstruction, or direct visualization, these devices measure and determine the size of particles within a detection area. On a built-in display, they typically display the concentration of particles and the number of particles at any given moment.
8. What is the accuracy of handheld airborne particle counters?
Handheld airborne particle counter accuracy is reliant upon several parameters, such as particle type being measured, sampling strategy, and device calibration. When calibrated and maintained correctly, modern handheld particle counters provide satisfactory precision within their designated range.
9. What restrictions apply to handheld airborne particle counters?
Restrictions can include the requirement for regular calibration and maintenance to maintain accuracy, sensitivity to environmental factors (such as temperature and humidity), and possible interference from background particles.
10. Are outdoor applications appropriate for It Handheld Airborne Particle Counters?
Yes, It counters are flexible for monitoring airborne particle levels in a variety of indoor and outdoor conditions. They are made for both field and laboratory applications.
11. What sizes of particles are detectable by handheld airborne particle counters?
particle counters can detect particles as small as 0.3 microns or smaller up to bigger particles as large as 5.0 microns.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.