Introduction

Digital Ultrasonic Cleaner offers a temperature range of 20 to 80°C for effective cleaning performance. It supports continuous and timed operation for flexible cleaning durations. Its ultrasonic frequency ensures effective cleaning of complex and delicate parts. The outer shell is made of durable stainless steel for enhanced corrosion resistance. Our cleaner is ideal for deep cleaning and pretreatment tasks across laboratories, electronics, medical, optical, and industrial components.

This ultrasonic cleaner is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Digital Ultrasonic Cleaner is ideal for deep cleaning and pretreatment tasks across laboratories, electronics, medical, optical, and industrial components with complex geometries and delicate surfaces.

Specifications

Capacity 30 L
Temperature Range 20 to 80°C
Ultrasonic Power 600 W
Heating Power 600W (220V), 500W (110V)
Timing 1 to 99 min
Washing Basket Optional
Frequency Working 27 ± 1.5 KHz
Cover Yes
Valve Drain Yes
Inner Tank Dimensions 490 x 290 x 195 mm
Packing Dimensions 657 x 450 x 475 mm
Gross Weight 20.7 kg

Features

Digital Display Control

High Q Transducers

Studless Welding Design

Strict Quality Control

Heating System

FAQs

1. What are the key factors to consider when selecting this ultrasonic cleaner for laboratory use?

When selecting this ultrasonic cleaner, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this ultrasonic cleaner be calibrated to ensure accurate results?

It is recommended to calibrate this ultrasonic cleaner at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this ultrasonic cleaner?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this ultrasonic cleaner be used with different types of samples, and are there any compatibility considerations?

Yes, this ultrasonic cleaner can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the ultrasonic cleaner malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

1. What is the temperature range of the Digital Ultrasonic Cleaner , and how does it benefit the cleaning process?

The Digital Ultrasonic Cleaner offers a temperature range of 20 to 80°C, which significantly enhances the efficiency of the cleaning process. Heating the cleaning solution helps to loosen stubborn contaminants like oils, greases, and residues from complex surfaces. The ability to adjust the temperature allows users to optimize cleaning for different materials and applications, ensuring that both delicate and heavy-duty components can be effectively cleaned without causing damage.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.