Introduction
Haematocrit Centrifuge can reach a maximum speed of 12000 rpm with an accuracy of ± 20 rpm. It operates with a brushless motor that provides rapid acceleration and deceleration for efficient processing. The centrifuge is equipped with advanced microprocessor control for precise performance. Its electronic lid lock enhances safety by preventing the lid from opening while the rotor is spinning. Our centrifuge is designed for testing hematocrit using capillary tubes and is widely used in clinics and laboratories.
It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.Applications
Our Haematocrit Centrifuge is used to determine hematocrit values by separating plasma from blood cells in capillary tubes. It is ideal for clinical laboratories, blood banks, and diagnostic centers.
Specifications
| Max Speed | 12000 rpm |
| Speed Accuracy | ± 20 rpm |
| Max | 15800 × g |
| Max Capacity | 24 pieces capillary tube |
| Run Time | 0 to 99 min 59 sec |
| / Rates | 10 |
| Display | |
| Noise | Up to 55 dB (A) |
| Power Supply | AC 110/220 V 50/60 Hz |
| Dimension | 355 × 270 × 205 mm |
| Net Weight | 13 kg |
Features
Real-time monitoring
Stainless steel chamber
and rpm convert function
Wide voltage range design
FAQs
1. What is the maximum sample volume that can be processed in the centrifuge?
The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.
2. How to balance the centrifuge before operation?
Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.
3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?
RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.
4. How to maintain the centrifuge to ensure long service life?
Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.
5. What safety precautions should be taken when using the centrifuge?
Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.
1. What is the maximum (Relative Centrifugal Force) generated by the Haematocrit Centrifuge ?
Haematocrit Centrifuge generates a maximum relative centrifugal force () of 15800 × g. is a measure of the actual force applied to the samples during centrifugation and directly affects the separation efficiency. This high ensures quick and precise stratification of blood components, making it suitable for time-sensitive diagnostic settings.
2. How many samples can the Haematocrit Centrifuge process at a time?
Haematocrit Centrifuge is equipped with a rotor that holds up to 24 capillary tubes. This capacity is optimal for medium-throughput environments, allowing technicians to process multiple samples simultaneously, thus improving overall laboratory efficiency without compromising performance.
3. Does the Haematocrit Centrifuge support dual voltage operation?
Yes, this Haematocrit Centrifuge is designed with a wide voltage compatibility, operating efficiently on both AC 110V and 220V power supplies at 50/60 Hz. This feature makes it versatile and suitable for global use in various laboratory environments without requiring additional voltage converters.
4. What safety mechanisms are integrated into the Haematocrit Centrifuge ?
Haematocrit Centrifuge includes an electronic lid locking system that prevents the lid from opening while the rotor is in motion. This ensures operator safety by eliminating the risk of accidental exposure to high-speed rotating components. Additionally, it operates with minimal vibration and noise, further contributing to a safe and comfortable lab environment.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.