Introduction
Vertical Autoclave supports a wide temperature range from 100 to 134°C, suitable for sterilizing various instruments. With a 50-liter chamber capacity and constructed entirely from high-grade stainless steel 304, it ensures long-lasting performance. Its microprocessor-based control system and digital display provide precise monitoring. It is ideal for facilities with limited space, while still delivering powerful sterilization performance.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Our Vertical Autoclave is widely used across medical, research, and industrial settings for reliable sterilization of equipment and materials.
Specifications
| Capacity | 50 L |
| Working Pressure | 0.22 MPa |
| Working Temperature | 100 to 134℃ |
| Sterilization Time | 0 to 9999 minutes |
| Temperature Display Accuracy | 0.1℃ |
| Heat Average | ≤±1℃ |
| Control System | Microprocessor |
| Display Type | Digital display |
| Door Type | Hand wheel quick open door |
| Steam Generator | Stainless steel 304 |
| Chamber Material | Fully stainless steel 304 |
| Loading Capacity | 1 pc stainless steel drum |
| Voltage | 110 to 220V, 50/60Hz |
| Power Consumption | 2.5 kW |
| Chamber Size | 50L / Ø318 × 530 mm |
| Outer Dimensions | 520 × 500 × 1000 mm |
| Packing Dimensions | 570 × 550 × 1090 mm |
| Net Weight | 49 kg |
| Gross Weight | 73 kg |
Features
Robust Construction
Precise Temperature Control
Wide Sterilization Range
Uniform Heat Distribution
User-Friendly Design
Energy Efficient
Compact and Portable
FAQs
1. What are the key features that make the Vertical Autoclave suitable for laboratory and medical sterilization processes?
The Vertical Autoclave is designed with a 50-liter stainless steel 304 chamber and steam generator, ensuring durability and corrosion resistance. Its microprocessor-controlled system allows precise sterilization cycles, with temperature accuracy up to 0.1°C and uniform heat distribution within ±1°C. The unit supports a wide temperature range from 100 to 134°C and offers a flexible sterilization time of up to 9999 minutes. These features make it highly reliable for sterilizing instruments, glassware, media, and more in laboratory and medical environments.
2. How does the Vertical Autoclave ensure consistent and effective sterilization performance?
The Vertical Autoclave ensures consistent performance through its advanced microprocessor control system and digital display, which precisely monitor and regulate temperature and time settings. Its robust stainless-steel chamber provides even heat distribution, while the hand wheel quick-open door design ensures a secure seal. The autoclave maintains heat uniformity within ±1°C, reducing the risk of sterilization failure due to temperature inconsistencies. This consistency is crucial for environments where contamination control is a priority.
3. In what types of facilities is the Vertical Autoclave most commonly used, and why is it preferred?
The Vertical Autoclave is commonly used in hospitals, research laboratories, pharmaceutical industries, microbiology labs, and food testing units. Its compact footprint (520 × 500 × 1000 mm) makes it ideal for facilities with limited space, while its 50L capacity provides sufficient room for routine sterilization of wrapped/unwrapped instruments, culture media, and laboratory tools. The ’s energy efficiency, combined with high-performance sterilization, makes it a preferred choice for institutions prioritizing safety, reliability, and space optimization.
4. What safety and user-friendly features are included in the Vertical Autoclave ?
The Vertical Autoclave is built with user safety and ease of operation in mind. It features a hand wheel quick-open door that provides secure sealing and easy access. The microprocessor-based control system ensures accurate operation, minimizing the chance of user error. Additionally, its fully stainless-steel construction enhances both safety and hygiene by preventing corrosion and bacterial growth. These thoughtful design choices reduce maintenance needs and ensure safe operation during high-pressure, high-temperature cycles.
5. What is the loading capacity of the Vertical Autoclave , and what materials can be sterilized in it?
The Vertical Autoclave supports a loading capacity of one stainless steel drum, optimized for the 50-liter chamber. This makes it suitable for sterilizing a wide range of materials including laboratory glassware, surgical instruments, rubber goods, culture media, and liquids. Its wide temperature and time range ensure compatibility with various load types that require different sterilization conditions, making it a versatile solution for multiple sterilization needs across diverse applications.