Introduction

Low Speed Centrifuge can reach a maximum speed of 5000 rpm with an accuracy of ± 10 rpm. It has a maximum capacity of 4 × 250 mL and is compatible with various stainless-steel autoclavable rotors. The centrifuge is equipped with advanced a variable-frequency motor for stable operation and enhanced durability. Its motorized door cannot be opened during operation, ensuring safety. Our centrifuge is suitable for laboratory applications that require low-speed centrifugation.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Our Low Speed Centrifuge is used in blood component separation, cell harvesting, and sample preparation for biochemical analysis. It is suitable for use in biology, medicine, chemistry, and environmental testing.

Specifications

Max Speed 5000 rpm
Speed Accuracy ± 10 rpm
Max 4650 × g
Capacity 4 × 250 mL
Timing Range 1 sec to 99 h 59 min 59 sec/ Pulse
Noise Up to 60 dB (A)
/ Rates 20 rates
Programs Up to 100
Power Consumption 500 W
Dimension 550 × 430 × 350 mm
Net Weight 39 kg

Features

Microprocessor control

Gas hinge for smooth lid operation

Variable frequency motor

Calibration/ operation port

Emergency door release

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.

1. What distinguishes the Low Speed Centrifuge in terms of performance and capacity?

Low Speed Centrifuge delivers a maximum rotational speed of 5000 rpm with a speed accuracy of ± 10 rpm. What sets this model apart is its larger sample handling capability, it supports up to 4 × 250 mL tubes in a single run, making it highly suitable for medium- to large-volume processing in clinical diagnostics, environmental labs, and research facilities. This combination of capacity and accuracy ensures that labs can perform high-throughput tasks without compromising on precision or consistency.

2. How does the Low Speed Centrifuge enhance safety and operator control during operation?

Safety is central to the design of the Low Speed Centrifuge . It features a motorized lid lock that automatically engages during operation, preventing the chamber from being opened until the rotor has come to a complete stop. Additionally, an emergency door release mechanism is available for safe manual override when required. These features ensure the protection of lab personnel while maintaining a secure environment for sensitive samples.

3. What makes the Low Speed Centrifuge a reliable choice for sample preparation in biomedical and environmental applications?

Low Speed Centrifuge is engineered with a variable frequency motor and microprocessor-based control system, which together ensure steady, vibration-free operation across a wide range of speeds and forces. The system includes 20 acceleration/deceleration profiles and up to 100 programmable memory slots, allowing users to tailor protocols to specific sample types, ranging from whole blood to cell suspensions and wastewater samples. This flexibility makes it ideal for diverse applications in biology, chemistry, and medical research.

4. What types of rotors and tubes are compatible with the Low Speed Centrifuge , and why is that important?

This Low Speed Centrifuge supports a wide array of swing-out rotors, accommodating tubes ranging from 2 mL to 250 mL in volume. These include configurations for 15 mL and 50 mL conical tubes, 100 mL blood bags, and even microplates. Rotors are made of stainless steel and are fully autoclavable, supporting sterile workflows. This broad compatibility gives labs the flexibility to use a single centrifuge across various sample types and protocols, reducing the need for multiple machines.