Introduction
Cooled Spectrometer is designed for high-precision spectral analysis that offers a wavelength range of 180 to 1100 nm. It has a built-in thermoelectric cooling system that cools the detector to –15°C, ensuring low thermal noise and stable signal output. The back-illuminated detector enhances quantum efficiency and reduces dark noise. Its high resolution in the range of 0.1 to 4.0 nm depending on the chosen slit and spectral range. Our Cooled Spectrometer is widely used for detailed material analysis, optical component testing, and scientific research.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Cooled Spectrometer is ideal for applications such as fluorescence detection, laser spectrum analysis, UV/visible/IR radiation testing, and characterisation. These systems are commonly deployed in material research, chemical labs, optical calibration, and environmental monitoring.
Specifications
| Detecting Spectral Wavelength | 180 to 1100 nm |
| Detector | Linear array back-illuminated |
| Effective Pixel Count | 1044 × 64 |
| Pixel Dimension | 24 µm × 24 µm |
| Storage Temperature | -20°C to 70°C |
| Operating Temperature | -10°C to 45°C |
| Focal Length | 98 mm (incidence), 107 mm (output) |
| Full-Scale Range | 600 ke |
| Entrance Slit Widths | 5, 10, 25, 50, 100, 150, 200 µm (customizable) |
| Sensitivity | 6.5 µV/e- |
| Dark Noise Level | 8e- |
| Optical Resolution | 0.01 to 1.3 nm (depends on slit width & spectral range) |
| Signal-to-Noise Ratio | At least 10000:1 |
| Dynamic Range | 50000:1 |
| Optical Design | F/4 cross asymmetric C-T optical path |
| Incident Light Interface | 905 fiber optic interface / Free space |
| Integration Time | 8 ms to 30 min |
| Data Output Interface | 2.0 |
| Bit Depth | 18 bit (output 18 bit) |
| Power Supply | DC 5V ±10% |
| Dimensions | 217 × 110 × 52 mm |
| Net Weight | 1.65 kg |
Features
High spectral resolution
Cross C-T optical path structure
Ultra-low noise circuitry
Compact and portable design
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.